RAID 10 – Mirror / Stripe<br />

251<br />

Chapter 8: <strong>Technology</strong> Background<br />

Mirror + Stripe combines both of the RAID 1 and RAID 0 logical drive types.<br />

RAID 10 can increase performance by reading and writing data in parallel—<br />

striping—while protecting data by duplicating it—mirroring.<br />

<strong>Promise</strong> implements RAID 10 by creating a data stripe over one pair of disk<br />

drives, then mirroring the stripe over a second pair of disk drives. Some<br />

applications refer to this method as RAID 0+1.<br />

Figure 6. <strong>Promise</strong> RAID 10 starts with a data stripe, then mirrors it<br />

1. Data Stripe<br />

Disk Drives<br />

2. Data Mirror<br />

The data capacity RAID 10 logical drive equals the capacity of the smallest<br />

physical drive times the number of physical drives, divided by two.<br />

In some cases, RAID 10 offers double fault tolerance, depending on which<br />

physical drives fail.<br />

RAID 10 arrays require an even number of physical drives and a minimum of<br />

four.<br />

For RAID 10 characteristics using an odd number of physical drives, choose<br />

RAID 1E.