Reported Event Corrective Action<br />

295<br />

Chapter 9: Troubleshooting<br />

Media patrol is queued Media patrol has been set manually or by schedule.<br />

Media patrol is stopped<br />

internally<br />

Media patrol stopped because the disk array was<br />

deleted or removed.<br />

Online Capacity Expansion<br />

Online capacity<br />

expansion has started<br />

Result of settings or user action. Normal.<br />

Online capacity<br />

expansion has completed<br />

Normal.<br />

Online capacity<br />

Expansion paused because of user intervention,<br />

expansion has paused schedule or higher priority background activity.<br />

Online capacity<br />

Expansion has resumed again after a pause or a<br />

expansion has resumed reboot.<br />

Online capacity<br />

Expansion stopped because of user intervention,<br />

expansion has stopped schedule or the logical drive was deleted or went<br />

critical or offline.<br />

Online capacity<br />

Bad block found on a disk drive. Migration will finish.<br />

expansion has<br />

Check the disk drive check table after migration and<br />

encountered a physical replace disk drive as needed. See page 106<br />

disk error<br />

(WebPAM PROe) or page 156 (CLU).<br />

Online capacity<br />

System resources are low. Reduce system load or<br />

expansion is aborted due restart the <strong>VessRAID</strong>. See page 94 (WebPAM PROe)<br />

to an internal error. or page 207 (CLU).<br />

Online capacity<br />

Synchronization has been set manually or by<br />

expansion is queued<br />

PDM<br />

schedule.<br />

PDM is started Result of settings or user action. Normal.<br />

PDM is completed Normal.<br />

PDM is paused PDM paused because of user intervention, schedule<br />

or a higher priority background activity.<br />

PDM is resumed PDM has resumed again after a pause.<br />

PDM is stopped PDM stopped because of user intervention, schedule<br />

or the logical drive was deleted or went critical or<br />

offline.<br />

PDM is switched to PDM changed to rebuild because the logical drive<br />

rebuild.<br />

went critical