Reported Event Corrective Action<br />

299<br />

Chapter 9: Troubleshooting<br />

Rebuild is resumed Rebuild has resumed again after a pause.<br />

Rebuild is stopped Rebuild stopped because of user intervention,<br />

schedule or the logical drive was deleted or the target<br />

disk drive encountered an error.<br />

If rebuild stopped by the user, restart the rebuild. See<br />

page 123 (WebPAM PROe) or page 164 (CLU).<br />

Rebuild stopped internally The logical drive is offline. See page 302.<br />

Rebuild is aborted due to System resources are low. Reduce system load or<br />

an internal error. restart the <strong>VessRAID</strong>. See page 94 (WebPAM PROe)<br />

or page 207 (CLU).<br />

Rebuild is queued Rebuild has been set manually or by schedule.<br />

Rebuild marks logical Result of successful rebuild. Normal.<br />

drive synchronized upon<br />

rebuild completion<br />

Redundancy Check<br />

Redundancy Check is<br />

started<br />

Redundancy Check is<br />

completed<br />

Redundancy Check is<br />

paused<br />

Redundancy Check is<br />

resumed<br />

Redundancy Check is<br />

stopped<br />

Redundancy Check is<br />

aborted due to internal<br />

error<br />

Redundancy Check<br />

encountered inconsistent<br />

block(s)<br />

Redundancy Check task<br />

is queued<br />

Redundancy Check task<br />

is stopped internally<br />

Redundancy Check has started manually or by<br />

schedule.<br />

Redundancy Check has finished.<br />

Redundancy Check paused because of user<br />

intervention, schedule or a higher priority background<br />

activity.<br />

Redundancy Check has resumed again after a<br />

pause.<br />

Redundancy Check stopped because of user<br />

intervention, schedule or the logical drive was deleted<br />

or went critical or offline. See page 302.<br />

System resources are low. Reduce system load or<br />

restart the <strong>VessRAID</strong>. See page 94 (WebPAM PROe)<br />

or page 207 (CLU).<br />

Check the logical drive’s inconsistent block table. See<br />

page 131. Rebuild the disk array if necessary. See<br />

page 114 (WebPAM PROe) or page 158 (CLU).<br />

Redundancy Check has been set manually or by<br />

schedule.<br />

The logical drive is offline. See page 302.