<strong>VessRAID</strong> 1000i Series Product Manual<br />

Reported Event Corrective Action<br />

Drive Interface Controller<br />

Drive-interface controller Normal.<br />

found<br />

Drive-interface controller Restart the <strong>VessRAID</strong>. See page 94 (WebPAM<br />

is NOT found<br />

PROe) or page 207 (CLU). If this message appears<br />

repeatedly, contact Technical Support. See page 319.<br />

Drive-interface<br />

Normal.<br />

diagnostics has passed<br />

Drive-interface<br />

Restart the <strong>VessRAID</strong>. See page 94 (WebPAM<br />

diagnostics has failed PROe) or page 207 (CLU). If this message appears<br />

repeatedly, contact Technical Support. See page 319<br />

Drive-interface controller Drive-to-controller parity error. If this message<br />

has generated a general/ appears repeatedly, contact Technical Support. See<br />

data parity error. page 319.<br />

Enclosure<br />

Enclosure temperature is The <strong>VessRAID</strong> is overheating. Check for airflow<br />

above the threshold/ around and through the <strong>VessRAID</strong>, and verify that all<br />

warning threshold fans are working. Replace fans as needed.<br />

Enclosure temperature is The <strong>VessRAID</strong> is seriously overheating. Check for<br />

above the critical airflow around and through the <strong>VessRAID</strong>, and verify<br />

threshold<br />

that all fans are working. Replace fans as needed.<br />

Enclosure temperature is Normal.<br />

within the normal range<br />

Event Log<br />

Event logging is enabled Event logging has been successfully enabled.<br />

Event logging is disabled Event logging has been disabled.<br />

Event log buffer is cleared The event log was cleared.<br />

in RAM<br />

Event log buffer is cleared The non-volatile RAM event log was cleared.<br />

in NVRAM<br />

Event log buffer is cleared The MDD (disk drive) event log was cleared.<br />

in MDD<br />

Host Interface Controller<br />

Host-interface controller<br />

has detected bus reset<br />

The initiator sent a reset command. If this message<br />

appears repeatedly, contact Technical Support. See<br />