179<br />

Chapter 5: Management with the CLU<br />

The screen displays the following information:<br />

• Controller ID – 1<br />

• Port ID – 1, 2, 3, or 4<br />

• Max Receive Data Segment Length – 8 KB is the default<br />

• Number of Active Sessions – Number of sessions logged into this port<br />

• Primary Header Digest Method – CRC-32<br />

• Primary Data Digest Method – CRC-32<br />

• iSCSI Receive Marker – None<br />

Viewing iSCSI Target Port Statistics<br />

You can see the target port settings, but none of these values are user-adjustable<br />

in the current version of the software.<br />

To view the iSCSI target port settings:<br />

1. From the Main Menu, highlight iSCSI Management and press Enter.<br />

2. Highlight iSCSI Ports and press Enter.<br />

3. Highlight Target Port 1, Target Port 2, Target Port 3, or Target Port 4 and<br />

press Enter.<br />

4. Highlight MAC Layer Statistics, IP Layer Statistics, or TCP Layer Statistics<br />

and press Enter.<br />

The screen displays statistics for the layer you chose.<br />

Viewing the iSCSI Portal<br />

An iSCSI Portal is an iSCSI data port.<br />

To view the iSCSI portals:<br />

1. From the Main Menu, highlight iSCSI Management and press Enter.<br />

2. Highlight iSCSI Portal and press Enter.<br />

The screen displays the following information:<br />

• Portal ID – 0 to 34<br />

• IP Address – IP address of the port<br />

• Associated Type – iSCSI<br />

• IF Name – Port number<br />

• TCP port number – 3260 is the default