Locating a Power Supply<br />

151<br />

Chapter 5: Management with the CLU<br />

To locate a power supply:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Power Supplies and press Enter.<br />

4. Highlight Locate Power Supply and press Enter.<br />

The LED on the selected power supply blinks for one minute.<br />

Viewing Cooling Unit Status<br />

To view the status of the blowers:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Cooling Units and press Enter.<br />

The screen displays the status and speed of <strong>VessRAID</strong>’s cooling fans. If the<br />

speed is below the Healthy Threshold, there is a fan malfunction. See<br />

“Replacing a Cooling Fan” on page 238.<br />

Viewing Voltage Sensor Status<br />

To view the status of the voltage sensors:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Voltage Sensors and press Enter.<br />

If any voltage is outside the Healthy Threshold values, there is a voltage<br />

malfunction in the enclosure. See “Chapter 9: Troubleshooting” on page 277.<br />

Viewing Temperature Sensor Status<br />

To view the status of the temperature sensors:<br />

1. From the Main Menu, highlight Subsystem Management and press Enter.<br />

2. Highlight Enclosure Management and press Enter.<br />

3. Highlight Temperature Sensors and press Enter.<br />

If any temperature exceeds the Healthy Threshold value, there is an<br />

overheat condition in the enclosure. See “Setting Temperature Thresholds”<br />

on page 152 and “Chapter 9: Troubleshooting” on page 277.