23.03.2013 Views

VessRAID Setup - Promise Technology, Inc.

VessRAID Setup - Promise Technology, Inc.

VessRAID Setup - Promise Technology, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>VessRAID</strong> 1000i Series Product Manual<br />

Figure 1.<br />

Viewing UPS Information<br />

To view information about a specific UPS unit:<br />

1. From the Main Menu, highlight Additional Info and Management and press<br />

Enter.<br />

2. Highlight UPS Management and press Enter.<br />

3. Highlight the UPS unit you want and press Enter.<br />

UPS information includes:<br />

• Voltage Rating – Output voltage of the UPS.<br />

• Battery Capacity – Backup capacity expressed as a percentage.<br />

• Remaining Backup Time – Number of minutes the UPS is expected to<br />

power your system in the event of a power failure.<br />

• Loading Ratio – Actual output of UPS as a percentage of the rated<br />

output. See the Note below.<br />

192<br />

Notes<br />

1. Detection Setting must be set to Auto. If a UPS is detected, the<br />

setting changes to Enable.<br />

2. The maximum recommended Loading Ratio varies among<br />

models of UPS units. The general range is 60% to 80%.<br />

Note<br />

The maximum recommended Loading Ratio varies among models<br />

of UPS units. The general range is 60% to 80%. If the reported<br />

Loading Ratio exceeds the recommended value for your UPS unit:<br />

• Have fewer subsystems or peripherals connected to this UPS<br />

unit.<br />

• Add more UPS units, or use a higher-capacity UPS unit, to<br />

protect your RAID systems.