221<br />

Managing Disk Arrays<br />

8. Press the<br />

choices.<br />

button to move to END and press the button to input your<br />

9. Press the button again to confirm.<br />

The display shows the array creation process. When the creation is finished,<br />

the LCD returns to Disk Array Create.<br />

Creating a Logical Drive<br />

For more information on the choices below, see “Chapter 8: <strong>Technology</strong><br />

Background” on page 245.<br />

To create a logical drive on your new disk array:<br />

1. Press the button and the display says Logical Disk Create.<br />

2. Press the button again and the display says 000.<br />

3. Press the button again and the display says RAID Level.<br />

4. Press the or button until the display shows the RAID level you want.<br />

Note that the available RAID levels depend on the number of physical drives<br />

in your disk array.<br />

5. Press the button to choose the RAID level shown on the screen.<br />

The display shows the maximum available capacity.<br />

6. Press the or button until the display shows the capacity you want.<br />

7. Press the button to choose the capacity shown on the screen.<br />

The display shows the default stripe size.<br />

The choices are 64 KB, 128 KB, 256 KB, 512 KB, and 1 MB.<br />

8. Press the or button until the display shows the stripe size you want.<br />

9. Press the button to choose the stripe size shown on the screen.<br />

The display shows the default sector size.<br />

The choices are 512 B; 1 KB, 2 KB, and 4 KB<br />

10. Press the or button until the display shows the sector size you want.<br />

The display shows the default read policy.<br />

The choices are ReadCache, ReadAhead and None.<br />

11. Press the or button until the display shows the read policy you want.<br />

12. Press the button to choose the read policy shown on the screen.<br />

The display shows the default write policy.<br />

The choices are WriteBack and WriteThru (write though).<br />

13. Press the or button until the display shows the write policy you want.<br />

14. Press the button to choose the write policy shown on the screen.