<strong>Inc</strong>omplete Array<br />

305<br />

Chapter 9: Troubleshooting<br />

An incomplete array can result from any of the following conditions:<br />

• The NVRAM watermark for the RAID level migration currently in progress is<br />

missing or cannot be found<br />

• A physical drive goes missing during transport<br />

See “Physical Drive Failed” on page 306 for more information.<br />

When <strong>VessRAID</strong> discovers an incomplete array, WebPAM PROe displays a<br />

dialog box asking you to:<br />

• Click the OK button to accept the incomplete array<br />

• Click the Cancel button to reject the incomplete array<br />

Before you accept the incomplete array, be sure all of the physical drives are<br />

present and that their drive carriers are properly installed into the enclosure. See<br />

“Installing Disk Drives” on page 15.<br />

If you choose to accept the incomplete array:<br />

1. Click OK in the incomplete array dialog box.<br />

2. Check the operational status of the logical drives in the array.<br />

• If the logical drives are critical or degraded, proceed with a rebuild.<br />

See “Rebuilding a Disk Array” on page 123 (WebPAM PROe) or<br />

page 164 (CLU).<br />

• If the logical drives are offline, contact Technical Support. See<br />

page 319.<br />

3. Restore your data from a backup source, if required.<br />

The CLU displays the option Accept <strong>Inc</strong>omplete Array on the Disk Array Info and<br />

Settings screen. Highlight the option and press Enter to accept the incomplete<br />

array.<br />

If you choose NOT to accept the incomplete array:<br />

1. Click Cancel in the incomplete array dialog box.<br />

2. Do one of the following:<br />

• Delete the array. See “Deleting a Disk Array” on page 119 (WebPAM<br />

PROe) or page 162 (CLU).<br />

• Replace the missing physical drive.