<strong>VessRAID</strong> 1000i Series Product Manual<br />

Critical & Offline Disk Arrays<br />

A fault-tolerant disk array—RAID 1, 1E, 5, 10, and 50—goes critical when a disk<br />

drive is removed or fails. A RAID 6 or 60 disk array—goes degraded when a disk<br />

drive is removed or fails and critical when two disk drives are removed of fail.<br />

Due to the fault tolerance of the disk array, the data is still available and online.<br />

However, once the disk array goes critical, the disk array has lost its fault<br />

tolerance, and performance may be adversely affected.<br />

If the fault was caused by a failed drive that was removed, the drive must be<br />

replaced by another drive, either identical or larger, in order for the RAID system<br />

to rebuild and restore optimal configuration.<br />

If your fault-tolerant disk array—RAID 1, 1E, 5, 6, 10, 50, and 60— goes offline,<br />

contact <strong>Promise</strong> Technical Support. See page 319.<br />

A non-fault tolerant disk array—RAID 0—goes offline when a disk drive is<br />

removed or fails. Since the disk array is not fault tolerant, the data stored in the<br />

disk array is no longer accessible.<br />

If one disk drive fails, all of the data on the disk array is lost. You must replace the<br />

failed drive. Then, if the disk array had more than one disk drive, delete the disk<br />

array and re-create it. Restore the data from a backup source.<br />

When a Physical Drive Fails<br />

<strong>VessRAID</strong> provides both audible and visual indicators to alert you of a disk drive<br />

failure. The following will occur when a disk drive fails or goes offline:<br />

• The Global RAID Status LED changes from green to amber.<br />

Figure 13.<strong>VessRAID</strong> front panel LEDs<br />

302<br />

Warning<br />

Take no further corrective action until you have consulted with<br />

<strong>Promise</strong> Technical Support.<br />

Power<br />

Global Enclosure Status<br />

Global RAID Status