By clicking on ADVANCED key<br />
in the section concerning injectors<br />
and other components, it is possible<br />
to display the injector characteristics.<br />
It is possible you have to<br />
read them to BRC technical<br />
Assistance service in case of problems.<br />
A similar section could be<br />
activated from the main<br />
screen, outside the aided procedure,<br />
by selecting Setting up --><br />
Type of Installation.<br />
4.2.1.3 Tem<strong>per</strong>ature sensors<br />
Calibration (only for CNG)<br />
It is the third step of the aided<br />
procedure in case of a CNG equipment;<br />
it is not displayed in case of<br />
a LPG one (see picture 4.1) and it<br />
is useful to calibrate the tem<strong>per</strong>ature<br />
sensor of the engine cooling<br />
water so that it can be read and<br />
used by the ECU.<br />
Choose sensor enabled if the<br />
original cooling water tem<strong>per</strong>ature<br />
sensor of the petrol engine has<br />
been connected (picture 4.5).<br />
By choosing this second option<br />
it is necessary to calibrate the sensor.<br />
To do it the vehicle has to be<br />
cold.<br />
If not it is possible, choose the<br />
option sensor Disabled in this section<br />
and calibrate it later, out of the<br />
aided procedure, through the suitable<br />
option from the Setting up<br />
menu.<br />
To calibrate the sensor follow<br />
this procedure:<br />
1. Select Sensor Enabled (see<br />
picture 4.6).<br />
2. Click on Calibration key.<br />
Pic. 4.4d - Aided Procedure – injectors and installation calibration by clicking on<br />
ADVANCED key in the injectors section<br />
Pic. 4.5 - Aided procedure – Tem<strong>per</strong>ature sensors calibration<br />
Pic. 4.6 - Aided procedure – Tem<strong>per</strong>ature sensors calibration – first value acquisition<br />
18