key. The possible selections are, in<br />
case of CNG or LPG turbo vehicle<br />
(picture 5.7):<br />
• SEQUENT P1<br />
TURBO/METANO Fuijkura<br />
(400kPa) pressure sensor<br />
In case of LPG installation (picture<br />
5.8):<br />
• SEQUENT P1 LPG Fuijkura<br />
(250kPa pressure sensor):<br />
• SEQUENT P1 LPG Motorola<br />
pressure sensor:<br />
The MAP sensor calibration can<br />
be executed in two ways, according<br />
to the available instruments:<br />
1.Calibration through P1<br />
manometer.<br />
2.Calibration through external<br />
manometer.<br />
The suggested o<strong>per</strong>ating conditions<br />
for the acquisition are:<br />
1.Engine off and ignition key on<br />
(pressure 1000 mbar)<br />
2.Engine at idle.<br />
5.4.1 CALIBRATION MAP<br />
THROUGH P1<br />
This option is based on the fact<br />
the P1 pressure sensor has been<br />
already set to execute the MAP<br />
calibration, too. The program will<br />
ask to disconnect the retroactive<br />
pipe for the Genius (hear the itself)<br />
and connect it to the P1 pressure<br />
sensor inlet (see picture 5.9).<br />
After this o<strong>per</strong>ation you just<br />
need to keep the changeover<br />
switch in petrol position, click on<br />
OK and follow the program indications.<br />
The calibration consists of the<br />
Pic. 5.7 - Setting up – calibration P1-M.A.P. calibration for CNG or LPG turbo<br />
vehicles with original MAP<br />
Pic. 5.8 - Setting up – calibration P1-MAP calibration for LPG vehicles with original MAP<br />
Fig. 5.9 - Setting up – MAP calibration through P1<br />