Figure 4.21Steady state mask full thermal balance subsystem<br />

The outputs are listed in Table 4.28 below.<br />

Table 4.28 Outputs from the steady state mask full thermal balance subsystem<br />

output port number output Unit<br />

1 Steady air temperature in the mask (for reference) °C<br />

2 Temperature of mask wall with heat dissipation °C<br />

(See Appendix XI for details of these subsystems)<br />

4.3.3.2 Mask air dynamic fluctuating thermal balance and condensation subsystem<br />

The purpose of this mask dynamic thermodynamic subsystem is to obtain the<br />

dynamically fluctuations of air temperature and specific humidity in the mask as well as<br />

the temperature and specific humidity of inhaled air. It contains four subsystems which<br />

will be shown and explained below.<br />