Figure XI. 4 Steady state mask wall temperature subsystem<br />

The inputs are listed in table below.<br />

Input port number Input Unit<br />

1 Steady air temperature in the mask (for reference) °C<br />

2 Average velocity in the mask(absolute value) m/s<br />

3 Length of the triangular plate inner surface m<br />

4 Half width of the triangular plate inner surface m<br />

5 Length of the triangular plate outer surface m<br />

6 Half width of the triangular plate outer surface m<br />

7 Ambient air temperature °C<br />

The contained subsystems are shown and explained below.<br />