VIII.2.3 Water surface mass transfer (evaporation) subsystem<br />

This water surface mass transfer (evaporation) subsystem is created based on Eq. (3.40).<br />

The mixed mass convection (evaporation) coefficient is calculated based on Eq. (3.44),<br />

Eq. (3.45) and Eq. (3.48).<br />

Inputs to this subsystem are listed below.<br />

Input port number Input Unit<br />

1 Relative pressure in the chamber Pascal<br />

2 Ambient air specific humidity In decimal<br />

3 Velocity of air flowing into the chamber m/s<br />

4 Water temperature °C<br />

5 Temperature of inlet to the chamber from ADU °C<br />

6 Portion of impact area to total water surface area In decimal<br />

The output of this subsystem is steady state evaporation rate which is required for<br />

calculating the water temperature and can also be used in comparison with dynamic<br />

state evaporation rate obtained from dynamic chamber-air thermal balance subsystem.<br />