Figure XII. 3 Inhaled air average temperature subsystem<br />

This subsystem is based on Eq. (3.99). The integration is controlled only over the<br />

inhalation phase.<br />

The inputs are listed in table below.<br />

Input port number Input Unit<br />

1 Fluctuating air temperature in the mask °C<br />

2 Breath load g/s<br />

XII.3 Dynamic fluctuating mask condensation/evaporation subsystem<br />

All the subsystems in it are the same as the ones for HADT lumps. For the foam-seal<br />

part, the input temperature is the air temperature (assumed isolated) and for the<br />

triangular plate, it is the wall temperature. The inputs are listed in table below.<br />

Input port number Input Unit<br />

1 Temperature of airflow into the mask °C<br />

2 Specific humidity of airflow into the mask In decimal<br />

3 Characteristic flow velocity on mask inner surfaces m/s<br />

4 Temperature of airflow into the mask °C<br />

5 Mask inner height m<br />

6 Length of the rectangular plates inner surface m<br />

7 Half width of the triangular plate inner surface m<br />