Diagnostics<br />

Table 4–2. DSA messages (cont.)<br />

Message<br />

Number Component Test State Description Action<br />

166-803xxx<br />

IMM IMM<br />

I2C Test<br />

Aborted IMM I2C<br />

test<br />

aborted:<br />

the node is<br />

busy; try<br />

later.<br />

1. Turn off the server <strong>and</strong> disconnect it<br />

from the power source. You must<br />

disconnect the server from AC<br />

power to reset the IMM.<br />

2. After 45 seconds, reconnect the<br />

server to the power source <strong>and</strong> turn<br />

on the server.<br />

3. Run the test again.<br />

4. Make sure that the DSA code is at<br />

the latest level. For the latest level<br />

of DSA code, go to the ES7000<br />

Model 7600R G2 Product <strong>Support</strong><br />

site page, <strong>and</strong> click the Drivers<br />

<strong>and</strong> Downloads option.<br />

5. Make sure that the server firmware<br />

is at the latest level. The installed<br />

firmware level is shown in the DSA<br />

event log in the Firmware/VPD<br />

section for this component. For the<br />

latest level of firmware, go to the<br />

ES7000 Model 7600R G2 Product<br />

<strong>Support</strong> site page, <strong>and</strong> click the<br />

Releases option.<br />

6. Run the test again.<br />

4–54 3850 7281–000