Table 4–2. DSA messages (cont.)<br />

Message<br />

Number Component Test State Description Action<br />

202-901xxx<br />

Memory Memory<br />

Stress<br />

Test<br />

Failed Test<br />

failure.<br />

1. Run the st<strong>and</strong>ard memory test to<br />

validate all memory.<br />

2. Make sure that the DSA code is at<br />

the latest level. For the latest level<br />

of DSA code, go to the ES7000<br />

Model 7600R G2 Product <strong>Support</strong><br />

site page, <strong>and</strong> click the Drivers<br />

<strong>and</strong> Downloads option.<br />

3. Turn off the server <strong>and</strong> disconnect it<br />

from power.<br />

4. Reseat the memory cards <strong>and</strong><br />

DIMMs (see Removing a DIMM <strong>and</strong><br />

Replacing a DIMM <strong>and</strong> see<br />

Removing a memory card <strong>and</strong><br />

Replacing the memory card ).<br />

5. Reconnect the server to power <strong>and</strong><br />

turn on the server.<br />

6. Run the test again.<br />

Diagnostics<br />

3850 7281–000 4–117