• If an action step is preceded by ″(Trained service technician only),″ that step must be<br />

performed only by a trained service technician.<br />

Symptom Action<br />

An embedded hypervisor<br />

device is not listed in the<br />

expected boot order, or is<br />

not in the list of boot<br />

devices, or a similar<br />

problem has occurred.<br />

General problems<br />

1. Make sure the embedded hypervisor device is selected in the<br />

boot menu (in the Setup utility <strong>and</strong> in Select Boot Device).<br />

2. If the embedded hypervisor is on an internal flash memory<br />

device, make sure that the internal flash memory device is<br />

seated in the connector correctly (see Removing the internal<br />

flash memory <strong>and</strong> Replacing the internal flash memory).<br />

3. See the documentation that comes with the embedded<br />

hypervisor for setup <strong>and</strong> configuration information.<br />

4. Make sure that other software works on the server.<br />

• Follow the suggested actions in the order in which they are listed in the Action column<br />

until the problem is solved.<br />

• See Table 5–1 to determine which components are customer replaceable units (CRU)<br />

<strong>and</strong> which components are field replaceable units (FRU).<br />

• If an action step is preceded by ″(Trained service technician only),″ that step must be<br />

performed only by a trained service technician.<br />

Symptom Action<br />

An LED is not working or<br />

a similar problem has<br />

occurred.<br />

Hard disk drive problems<br />

Diagnostics<br />

If the part is a CRU, replace it. If the part is a FRU, the part must be<br />

replaced by a trained service technician (see Replaceable server<br />

components to determine whether the part is a CRU or a FRU).<br />

• Follow the suggested actions in the order in which they are listed in the Action column<br />

until the problem is solved.<br />

• See Table 5–1 to determine which components are customer replaceable units (CRU)<br />

<strong>and</strong> which components are field replaceable units (FRU).<br />

• If an action step is preceded by ″(Trained service technician only),″ that step must be<br />

performed only by a trained service technician.<br />