Introduction<br />

Power-on LED: See Operator information panel for the various states of the power-on<br />

LED.<br />

The following table describes the problems that are indicated by various combinations of<br />

the power-supply LEDs <strong>and</strong> the power-on LED on the operator information panel <strong>and</strong><br />

suggested actions to correct the detected problems.<br />

Power-supply LEDs<br />

AC DC Error<br />

Off Off Off No AC<br />

power to<br />

either power<br />

supply or a<br />

problem<br />

with the AC<br />

power<br />

source<br />

Off Off On No AC<br />

power to<br />

the server or<br />

a problem<br />

with the AC<br />

power<br />

source <strong>and</strong><br />

the power<br />

supply had<br />

detected an<br />

internal<br />

problem<br />

Off On Off Faulty<br />

power<br />

supply<br />

Off On On Faulty<br />

power<br />

supply<br />

Table 3–1. Power-supply LEDs<br />

Description Action Notes<br />

1. Check the AC power to<br />

the server.<br />

2. Make sure that the power<br />

cord is connected to a<br />

functioning power source.<br />

3. Turn the server off <strong>and</strong><br />

then turn the server back<br />

on.<br />

4. If the problem remains,<br />

replace the power supply.<br />

1. Replace the power supply.<br />

2. Make sure that the power<br />

cord is connected to a<br />

functioning power source.<br />

Replace the power supply.<br />

Replace the power supply.<br />

This is a<br />

normal<br />

condition<br />

when no AC<br />

power is<br />

present.<br />

This happens<br />

only when a<br />

second power<br />

supply is<br />

providing<br />

power to the<br />

server.<br />

3–12 3850 7281–000