8. EXPLOSION PROTECTED TYPE INSTRUMENT<br />
(Remote Flowtube)<br />
WARNING<br />
• De-energize before opening.<br />
• Take care not to generate mechanical spark<br />
when access to the instrument and peripheral<br />
devices in hazardous locations.<br />
(5) Maintenance and Repair<br />
WARNING<br />
The instrument modification or parts replacement<br />
by other than authorized representative of<br />
<strong>Yokogawa</strong> Electric Corporation is prohibited and<br />
will void the certification.<br />
No.: KEMA 03ATEX2435:<br />
EC Type Examination certificate number<br />
EEx dme[ia]IIC T6...T3: Protection type and temp. class<br />
ELECTRODE CIRCUIT Um: Voltage of electrode circuit<br />
ENCLOSURE: Enclosure protection code<br />
WARNING: Warning to apparatus<br />
YOKOGAWA TOKYO 180-8750 JAPAN :<br />
Name and address of manufacturer<br />
*1) The third figure from the last shows the last one<br />
figure of the year of production. For example, the<br />
year of production of the product engraved as<br />
follows is year 2003.<br />
No. F261GA091 313<br />
↑<br />
Produced in 2003<br />
*2) The identification number of the notified body :<br />
0344 KEMA Netherland<br />
*3) The product-producing country<br />
*4) In case of the sizes of 2.5 to 25mm (0.1 to 1.0<br />
in.) , “0038” is not described.<br />
(6) Data Plate<br />
(<strong>Integral</strong> <strong>Flowmeter</strong>)<br />
L<br />
H<br />
mm<br />
MPa MAX.<br />
˚C<br />
˚C<br />
VAC<br />
VDC 12W<br />
50/60Hz 30VA 12W<br />
mA (0-750 Ω)<br />
VDC 0.2A MAX.<br />
2G No.: KEMA03ATEX2435<br />
Tamb: –40 TO +60 °C<br />
1D EEx dme [ia] C T6...T3<br />
TEMP. CLASS T6 T5 T4 T3<br />
*2) 0344<br />
ENCLOSURE: IP66, IP67<br />
MAX.PROCESS TEMP.(˚C) +70 +85 +120 +130<br />
*4) 0038<br />
ELECTRODE CIRCUIT Um: 250Vac/dc MAX. SURFACE TEMP.<br />
FOR DUST-PROOF T75°C T85°CT100°C T110°C<br />
Made in *3)<br />
WARNING<br />
User’s <strong>Manual</strong><br />
TOKYO 180-8750 JAPAN<br />
(Remote Flowtube)<br />
L<br />
H<br />
MPa MAX.<br />
˚C<br />
˚C<br />
mm<br />
Made in *3)<br />
COMB.NO.<br />
No.: KEMA03ATEX2435 F9805AG<br />
2G EEx dme [ia] C T6...T3<br />
1D ENCLOSURE: IP66,IP67<br />
*2) 0344<br />
ELECTRODE CIRCUIT Um: 250Vac/dc<br />
*4) 0038<br />
Tamb: –40 TO +60 °C<br />
WARNING TEMP. CLASS T6 T5 T4 T3<br />
User’s <strong>Manual</strong><br />
MAX.PROCESS TEMP.(˚C) +70 +85 +120 +150<br />
MAX. SURFACE TEMP.<br />
FOR DUST-PROOF<br />
T75°C T85°C T100°C T115°C<br />
TOKYO 180-8750 JAPAN<br />
MODEL: Specified model code<br />
SUFFIX: Suffix codes of the model code<br />
STYLE: Specified style code<br />
SIZE: Nominal size of apparatus<br />
METER FACTOR: Sensor constant number of apparatus<br />
SUPPLY: Power supply voltage of apparatus<br />
OUTPUT: Output signal of apparatus<br />
FLUID TEMP.: Fluid temperature of apparatus<br />
FLUID PRESS: Fluid pressure of apparatus<br />
AMB. TEMP., Tamb: Ambient temperature<br />
No.: Manufacturing serial number *1)<br />
CE: CE marking<br />
II 2G: Group II Category 2 Gas atmosphere<br />
II 1D: Group II Category 1 Dust atmosphere<br />
8-3<br />
IM 01E20D01-01E