User's Manual AXF Magnetic Flowmeter Integral ... - Yokogawa
User's Manual AXF Magnetic Flowmeter Integral ... - Yokogawa
User's Manual AXF Magnetic Flowmeter Integral ... - Yokogawa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
8. EXPLOSION PROTECTED TYPE INSTRUMENT<br />
<strong>Magnetic</strong> <strong>Flowmeter</strong><br />
8.3 CSA<br />
HAZARDOUS LOCATIONS<br />
Conduit<br />
18" (457 mm) Max.<br />
Figure 8.2.1 Conduit Wiring<br />
Sealing Fitting<br />
F0802.EPS<br />
(1) Technical Data<br />
*<strong>AXF</strong>002C – <strong>AXF</strong>400C<br />
Applicable Standard:<br />
For CSA C22.2 Series;<br />
C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,<br />
C22.2 No 25, C22.2 No 30, C22.2 No 94,<br />
C22.2 No 157, C22.2 No 1010.1<br />
For CSA E79 Series;<br />
CAN/CSA-E79-0, CAN/CSA-E79-1,<br />
CAN/CSA-E79-7, CAN/CSA-E79-11,<br />
CAN/CSA-E79-18<br />
Certificate: 1481213<br />
(<strong>Integral</strong> <strong>Flowmeter</strong>)<br />
For CSA C22. 2 Series<br />
Explosion proof for Class I, Division 1, Groups A,<br />
B, C & D.<br />
Dust-ignition proof for Class II/III, Division 1,<br />
Groups E, F & G.<br />
Intrinsically safe (electrodes) for Class I, Division 1,<br />
Groups A, B, C & D.<br />
“SEAL ALL CONDUITS WITHIN 50 cm OF THE<br />
ENCLOSURE”<br />
“WHEN INSTALLED IN DIV. 2, SEALS NOT<br />
REQUIRED”<br />
Electrode Circuit Um: 250 Vac/dc<br />
Maximum power supply voltage: 250 Vac/130 Vdc<br />
Excitation Circuit: 140V max<br />
Enclosure: Type 4X<br />
Temperature Code:<br />
Temperature<br />
Code<br />
T6<br />
T5<br />
T4<br />
T3<br />
Maximum Process<br />
Temperature<br />
+70°C (+158°F)<br />
+85°C (+185°F)<br />
+120°C (+248°F)<br />
+130°C (+266°F)<br />
Minimum Process<br />
Temperature<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
T27-1.EPS<br />
Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />
For CSA E79 Series<br />
Flameproof for Zone 1, Ex dme [ia] IIC T6...T3<br />
Intrinsically safe (electrodes), Ex ia IIC T6...T3<br />
Electrode Circuit Um: 250 Vac/dc<br />
Maximum power supply voltage: 250 Vac/130 Vdc<br />
Excitation Circuit: 140V max<br />
Enclosure: IP66, IP67<br />
Temperature Code:<br />
Temperature<br />
Code<br />
T6<br />
T5<br />
T4<br />
T3<br />
Maximum Process<br />
Temperature<br />
+70°C (+158°F)<br />
+85°C (+185°F)<br />
+120°C (+248°F)<br />
+130°C (+266°F)<br />
Minimum Process<br />
Temperature<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
T0807.EPS<br />
Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />
(Remote Flowtube)<br />
For CSA C22.2 Series<br />
Explosion proof for Class I, Division 1, Groups A,<br />
B, C & D.<br />
Dust-ignition proof for Class II/III, Division 1,<br />
Groups E, F & G.<br />
Intrinsically safe (electrodes) for Class I, Division 1,<br />
Groups A, B, C & D.<br />
“SEAL ALL CONDUITS WITHIN 50 cm OF THE<br />
ENCLOSURE”<br />
“WHEN INSTALLED IN DIV. 2, SEALS NOT<br />
REQUIRED”<br />
Electrode Circuit Um: 250 Vac/dc<br />
Excitation Circuit: 170V max<br />
Enclosure: Type 4X<br />
Temperature Code:<br />
Temperature<br />
Code<br />
T6<br />
T5<br />
T4<br />
T3<br />
Maximum Process<br />
Temperature<br />
+70°C (+158°F)<br />
+85°C (+185°F)<br />
+120°C (+248°F)<br />
+150°C (+302°F)<br />
Minimum Process<br />
Temperature<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
–40°C (–40°F)<br />
Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />
T28-1.EPS<br />
For CSA E79 Series<br />
Flameproof for Zone 1, Ex dme [ia] IIC T6...T3<br />
Intrinsically safe (electrodes), Ex ia IIC T6...T3<br />
Electrode Circuit Um: 250 Vac/dc<br />
Excitation Circuit: 170V max<br />
Enclosure: IP66, IP67<br />
8-5<br />
IM 01E20D01-01E