8. EXPLOSION PROTECTED TYPE INSTRUMENT<br />

<strong>Magnetic</strong> <strong>Flowmeter</strong><br />

8.3 CSA<br />

HAZARDOUS LOCATIONS<br />

Conduit<br />

18" (457 mm) Max.<br />

Figure 8.2.1 Conduit Wiring<br />

Sealing Fitting<br />

F0802.EPS<br />

(1) Technical Data<br />

*<strong>AXF</strong>002C – <strong>AXF</strong>400C<br />

Applicable Standard:<br />

For CSA C22.2 Series;<br />

C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,<br />

C22.2 No 25, C22.2 No 30, C22.2 No 94,<br />

C22.2 No 157, C22.2 No 1010.1<br />

For CSA E79 Series;<br />

CAN/CSA-E79-0, CAN/CSA-E79-1,<br />

CAN/CSA-E79-7, CAN/CSA-E79-11,<br />

CAN/CSA-E79-18<br />

Certificate: 1481213<br />

(<strong>Integral</strong> <strong>Flowmeter</strong>)<br />

For CSA C22. 2 Series<br />

Explosion proof for Class I, Division 1, Groups A,<br />

B, C & D.<br />

Dust-ignition proof for Class II/III, Division 1,<br />

Groups E, F & G.<br />

Intrinsically safe (electrodes) for Class I, Division 1,<br />

Groups A, B, C & D.<br />

“SEAL ALL CONDUITS WITHIN 50 cm OF THE<br />

ENCLOSURE”<br />

“WHEN INSTALLED IN DIV. 2, SEALS NOT<br />

REQUIRED”<br />

Electrode Circuit Um: 250 Vac/dc<br />

Maximum power supply voltage: 250 Vac/130 Vdc<br />

Excitation Circuit: 140V max<br />

Enclosure: Type 4X<br />

Temperature Code:<br />

Temperature<br />

Code<br />

T6<br />

T5<br />

T4<br />

T3<br />

Maximum Process<br />

Temperature<br />

+70°C (+158°F)<br />

+85°C (+185°F)<br />

+120°C (+248°F)<br />

+130°C (+266°F)<br />

Minimum Process<br />

Temperature<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

T27-1.EPS<br />

Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />

For CSA E79 Series<br />

Flameproof for Zone 1, Ex dme [ia] IIC T6...T3<br />

Intrinsically safe (electrodes), Ex ia IIC T6...T3<br />

Electrode Circuit Um: 250 Vac/dc<br />

Maximum power supply voltage: 250 Vac/130 Vdc<br />

Excitation Circuit: 140V max<br />

Enclosure: IP66, IP67<br />

Temperature Code:<br />

Temperature<br />

Code<br />

T6<br />

T5<br />

T4<br />

T3<br />

Maximum Process<br />

Temperature<br />

+70°C (+158°F)<br />

+85°C (+185°F)<br />

+120°C (+248°F)<br />

+130°C (+266°F)<br />

Minimum Process<br />

Temperature<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

T0807.EPS<br />

Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />

(Remote Flowtube)<br />

For CSA C22.2 Series<br />

Explosion proof for Class I, Division 1, Groups A,<br />

B, C & D.<br />

Dust-ignition proof for Class II/III, Division 1,<br />

Groups E, F & G.<br />

Intrinsically safe (electrodes) for Class I, Division 1,<br />

Groups A, B, C & D.<br />

“SEAL ALL CONDUITS WITHIN 50 cm OF THE<br />

ENCLOSURE”<br />

“WHEN INSTALLED IN DIV. 2, SEALS NOT<br />

REQUIRED”<br />

Electrode Circuit Um: 250 Vac/dc<br />

Excitation Circuit: 170V max<br />

Enclosure: Type 4X<br />

Temperature Code:<br />

Temperature<br />

Code<br />

T6<br />

T5<br />

T4<br />

T3<br />

Maximum Process<br />

Temperature<br />

+70°C (+158°F)<br />

+85°C (+185°F)<br />

+120°C (+248°F)<br />

+150°C (+302°F)<br />

Minimum Process<br />

Temperature<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

–40°C (–40°F)<br />

Ambient Temp.: –40°C to +60°C (–40°F to +140°F)<br />

T28-1.EPS<br />

For CSA E79 Series<br />

Flameproof for Zone 1, Ex dme [ia] IIC T6...T3<br />

Intrinsically safe (electrodes), Ex ia IIC T6...T3<br />

Electrode Circuit Um: 250 Vac/dc<br />

Excitation Circuit: 170V max<br />

Enclosure: IP66, IP67<br />

8-5<br />

IM 01E20D01-01E