6. OUTLINE<br />

<strong>AXF</strong> Standard, <strong>AXF</strong>150, <strong>AXF</strong>200, Wafer Type, Ceramics Lining<br />

<strong>AXF</strong>150 G<br />

<strong>AXF</strong>200 C<br />

*3<br />

D<br />

E 1<br />

F 2<br />

N N<br />

P<br />

*3: D, E, F; <strong>Integral</strong> <strong>Flowmeter</strong>,<br />

N, P; Remote Flowtube<br />

C E 1 A 1<br />

<strong>Integral</strong> <strong>Flowmeter</strong><br />

154(6.06)<br />

Remote Flowtube<br />

Ground Terminal<br />

(M4)<br />

ø86<br />

48<br />

(3.38)<br />

(1.89)<br />

Unit : mm (approx. inch)<br />

<strong>Integral</strong> <strong>Flowmeter</strong> Remote Flowtube<br />

Ground Terminal<br />

(M4)<br />

197(7.76)* 1<br />

66* 1<br />

(2.6)<br />

51.5 51.5<br />

(2.03) (2.03)<br />

28(1.1)<br />

111(4.37)<br />

Hr<br />

H1<br />

Hi<br />

73<br />

(2.87)<br />

49<br />

(1.93)<br />

70(2.76)<br />

ø128(5.04)<br />

(ød)<br />

øD<br />

* No infra-red switches are furnished<br />

for Fieldbus communication type.<br />

L* 2<br />

Model<br />

Remote<br />

Flowtube<br />

Size code<br />

Size<br />

Lining code<br />

Face-to-face<br />

length<br />

Outside dia.<br />

L *2<br />

D<br />

150<br />

150(6)<br />

C<br />

232(9.13)<br />

214(8.43)<br />

200<br />

200(8)<br />

C<br />

302(11.89)<br />

264(10.39)<br />

*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the<br />

value in the figure.<br />

In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.<br />

*2: Depending on the selection of grounding ring code and optional code,<br />

add the following value to L (face-to-face length).<br />

Grounding Ring Code S, L, H, V P, T N<br />

L(Face-to-face length) +0 +30(1.18) -6(0.24)<br />

<strong>Integral</strong><br />

<strong>Flowmeter</strong><br />

Inner diameter of<br />

Grounding ring<br />

Height<br />

ød<br />

H1<br />

144(5.67)<br />

254(10.00)<br />

192(7.56)<br />

304(11.97)<br />

Remote<br />

Flowtube<br />

Max. Height<br />

Weight kg (lb)<br />

Hr<br />

378(14.88)<br />

20.2(44.5)<br />

428(16.85)<br />

33.5(73.9)<br />

<strong>Integral</strong><br />

<strong>Flowmeter</strong><br />

Max. Height<br />

Weight kg (lb)<br />

Hi<br />

416(16.36)<br />

466(18.33)<br />

21.9(48.3) 35.2(77.6)<br />

F28.EPS<br />

6-37<br />

IM 01E20D01-01E