REVISION RECORD<br />
Title: <strong>AXF</strong> <strong>Magnetic</strong> <strong>Flowmeter</strong> <strong>Integral</strong> <strong>Flowmeter</strong>/Remote Flowtube<br />
[Hardware Edition]<br />
<strong>Manual</strong> No.: IM 01E20D01-01E<br />
Edition Date Page Revised Item<br />
6th Oct. 2005 3-22 to 3-24 Added the "Confirmation of adapter mounting screw"<br />
5-1 (7) Added the sentence.<br />
5-5 Added the note of installation<br />
6-7 Added the note of permeable fluids to the grounding ring/grounding<br />
electrode.<br />
6-12 Added the "IECEx" to the hazardous area classification.<br />
6-14 Added the "SF2 (IECEx)" to the withstand voltage.<br />
6-21 to 6-27 Changed the note for wetted parts material.<br />
6-28 MU Changed description of the "mass unit setting (MU)".<br />
6-29 PM Changed the value of the mirror finished PFA lining (PM).<br />
Changed from "Ra 0.05 to 0.15 µm" to "Size 15 to 200 mm :<br />
Ra 0.05 to 0.15 µm, Size 250 to 400 mm : Ra 0.05 to 0.25 µm"<br />
6-31 SF2 Added the "IECEx Certification (SF2)" to the optional specifications.<br />
6-39 Corrected the "Weight kg (lb)" of BD4.<br />
6-40 Corrected the "Weight kg (lb)" of BJ1/CJ1, BJ2/CJ2 and BG1/CG1.<br />
6-48 Corrected the "Inner diameter of grounding ring (ød)" of size 250mm.<br />
8-7 to 8-8 8.5 Added the "IECEx".<br />
7th June 2006 1-1 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
3-11 Table 3.3.7 Changed the Torque Value.<br />
3-12 Table 3.3.8 Changed the Torque Value.<br />
3-13 Table 3.3.9 Changed the Torque Value.<br />
3-16 Table 3.3.14 Changed the Torque Value.<br />
3-17 Table 3.3.15 Changed the Torque Value.<br />
3-18 Table 3.3.16 Changed the Torque Value.<br />
3-22 5) Added the sentence.<br />
3-23 5) Added the sentence.<br />
3-24 5) Added the sentence.<br />
Changed the Figure 3.3.10.<br />
4-3 (2) Added the postscript about FOUNDATION Fieldbus protocol type.<br />
4-6 (6) Added the postscript about FOUNDATION Fieldbus protocol type.<br />
4-13 1), 2) Added the “IECEx”.<br />
5-5 5.3 Added the CAUTION.<br />
Changed the Figure 5.3.1.<br />
5-8 5.4.3 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
5-9 5.5.1 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
5-10 5.5.2 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
6-1, 14, 20, 28 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
6-7 Corrected from “SPCC” to “SS400” in Housing of size 500 mm to<br />
2600 mm<br />
6-17 to 20 Corrected the value of Pressure on figure.<br />
6-21 to 6-23 Added the “-F” (FOUNDATION Fieldbus protocol).<br />
6-25 to 6-27 Added the “-F” (FOUNDATION Fieldbus protocol).<br />
6-34 to 6-48 Added the postscript about FOUNDATION Fieldbus protocol type.<br />
IM 01E20D01-01E