8.4 IECEx<br />
WARNING<br />
Only trained persons use this instrument in<br />
industrial locations.<br />
(1) Technical Data<br />
*<strong>AXF</strong>002C – <strong>AXF</strong>400C<br />
Applicable Standard:<br />
IEC60079-0: 2004, IEC60079-1: 2003,<br />
IEC60079-7: 2001, IEC60079-11: 1999,<br />
IEC60079-18: 2004,<br />
IEC61241-0: 2004, IEC61241-1: 2004,<br />
IEC60529: 1999 + Edition 2.1: 2001<br />
Certificate: IECEx KEM 05.0018<br />
(<strong>Integral</strong> <strong>Flowmeter</strong>)<br />
IECEx Flameproof Type<br />
Ex demb[ia] IIC T6...T3<br />
Electrode Circuit Um: 250 Vac/dc<br />
Maximum power supply voltage: 250 Vac/130 Vdc<br />
Excitation Circuit: 140V max<br />
Enclosure: IP66, IP67<br />
Temperature Class:<br />
Temperature<br />
Class<br />
T6<br />
T5<br />
T4<br />
T3<br />
Process Temperature<br />
–40°C to +70°C (–40°F to +158°F)<br />
–40°C to +85°C (–40°F to +185°F)<br />
–40°C to +120°C (–40°F to +248°F)<br />
–40°C to +130°C (–40°F to +266°F)<br />
T0809.EPS<br />
Ambient Temp.:<br />
PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />
Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />
IECEx Type of Protection "Dust"<br />
Ex tD A21 IP6x T95˚C, T105˚C, T120˚C, T130˚C<br />
Electrode Circuit Um: 250 Vac/dc<br />
Maximum power supply voltage: 250 Vac/130 Vdc<br />
Excitation Circuit: 140V max<br />
Enclosure: IP66, IP67<br />
Maximum surface temperature:<br />
Maximum Surface<br />
Temperature<br />
T95°C (+203°F)<br />
T105°C (+221°F)<br />
T120°C (+248°F)<br />
T130°C (+266°F)<br />
Process Temperature<br />
–40°C to +70°C (–40°F to +158°F)<br />
–40°C to +85°C (–40°F to +185°F)<br />
–40°C to +120°C (–40°F to +248°F)<br />
–40°C to +130°C (–40°F to +266°F)<br />
T0810.EPS<br />
Ambient Temp.:<br />
PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />
Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />
8-7<br />
8. EXPLOSION PROTECTED TYPE INSTRUMENT<br />
(Remote Flowtube)<br />
IECEx Flameproof Type<br />
Ex demb[ia] IIC T6...T3<br />
Electrode Circuit Um: 250 Vac/dc<br />
Excitation Circuit: 170V max<br />
Enclosure: IP66, IP67<br />
Temperature Class:<br />
Temperature<br />
Class<br />
T6<br />
T5<br />
T4<br />
T3<br />
Process Temperature<br />
–40°C to +70°C (–40°F to +158°F)<br />
–40°C to +85°C (–40°F to +185°F)<br />
–40°C to +120°C (–40°F to +248°F)<br />
–40°C to +150°C (–40°F to +302°F)<br />
T0811.EPS<br />
Ambient Temp.:<br />
PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />
Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />
IECEx Type of Protection "Dust"<br />
Ex tD A21 IP6x T95˚C, T105˚C, T120˚C, T135˚C<br />
Electrode Circuit Um: 250 Vac/dc<br />
Excitation Circuit: 170V max<br />
Enclosure: IP66, IP67<br />
Maximum surface temperature:<br />
Maximum Surface<br />
Temperature<br />
T95°C (+203°F)<br />
T105°C (+221°F)<br />
T120°C (+248°F)<br />
T135°C (+275°F)<br />
Process Temperature<br />
–40°C to +70°C (–40°F to +158°F)<br />
–40°C to +85°C (–40°F to +185°F)<br />
–40°C to +120°C (–40°F to +248°F)<br />
–40°C to +150°C (–40°F to +302°F)<br />
T0812.EPS<br />
Ambient Temp.:<br />
PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />
Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />
(2) Installation<br />
WARNING<br />
•All wiring shall comply with local installation<br />
requirements and local electrical code.<br />
• In hazardous locations, the cable entry devices<br />
shall be of a certified IECEx flameproof type,<br />
suitable for the conditions of use and correctly<br />
installed.<br />
• Unused apertures shall be closed with suitable<br />
flameproof certified blanking elements. (The<br />
plug attached is certified as the flameproof and<br />
IP66 or IP67 as a part of this apparatus.)<br />
• In case of ANSI 1/2 NPT plug, ANSI hexagonal<br />
wrench should be applied to screw in.<br />
IM 01E20D01-01E