8.4 IECEx<br />

WARNING<br />

Only trained persons use this instrument in<br />

industrial locations.<br />

(1) Technical Data<br />

*<strong>AXF</strong>002C – <strong>AXF</strong>400C<br />

Applicable Standard:<br />

IEC60079-0: 2004, IEC60079-1: 2003,<br />

IEC60079-7: 2001, IEC60079-11: 1999,<br />

IEC60079-18: 2004,<br />

IEC61241-0: 2004, IEC61241-1: 2004,<br />

IEC60529: 1999 + Edition 2.1: 2001<br />

Certificate: IECEx KEM 05.0018<br />

(<strong>Integral</strong> <strong>Flowmeter</strong>)<br />

IECEx Flameproof Type<br />

Ex demb[ia] IIC T6...T3<br />

Electrode Circuit Um: 250 Vac/dc<br />

Maximum power supply voltage: 250 Vac/130 Vdc<br />

Excitation Circuit: 140V max<br />

Enclosure: IP66, IP67<br />

Temperature Class:<br />

Temperature<br />

Class<br />

T6<br />

T5<br />

T4<br />

T3<br />

Process Temperature<br />

–40°C to +70°C (–40°F to +158°F)<br />

–40°C to +85°C (–40°F to +185°F)<br />

–40°C to +120°C (–40°F to +248°F)<br />

–40°C to +130°C (–40°F to +266°F)<br />

T0809.EPS<br />

Ambient Temp.:<br />

PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />

Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />

IECEx Type of Protection "Dust"<br />

Ex tD A21 IP6x T95˚C, T105˚C, T120˚C, T130˚C<br />

Electrode Circuit Um: 250 Vac/dc<br />

Maximum power supply voltage: 250 Vac/130 Vdc<br />

Excitation Circuit: 140V max<br />

Enclosure: IP66, IP67<br />

Maximum surface temperature:<br />

Maximum Surface<br />

Temperature<br />

T95°C (+203°F)<br />

T105°C (+221°F)<br />

T120°C (+248°F)<br />

T130°C (+266°F)<br />

Process Temperature<br />

–40°C to +70°C (–40°F to +158°F)<br />

–40°C to +85°C (–40°F to +185°F)<br />

–40°C to +120°C (–40°F to +248°F)<br />

–40°C to +130°C (–40°F to +266°F)<br />

T0810.EPS<br />

Ambient Temp.:<br />

PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />

Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />

8-7<br />

8. EXPLOSION PROTECTED TYPE INSTRUMENT<br />

(Remote Flowtube)<br />

IECEx Flameproof Type<br />

Ex demb[ia] IIC T6...T3<br />

Electrode Circuit Um: 250 Vac/dc<br />

Excitation Circuit: 170V max<br />

Enclosure: IP66, IP67<br />

Temperature Class:<br />

Temperature<br />

Class<br />

T6<br />

T5<br />

T4<br />

T3<br />

Process Temperature<br />

–40°C to +70°C (–40°F to +158°F)<br />

–40°C to +85°C (–40°F to +185°F)<br />

–40°C to +120°C (–40°F to +248°F)<br />

–40°C to +150°C (–40°F to +302°F)<br />

T0811.EPS<br />

Ambient Temp.:<br />

PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />

Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />

IECEx Type of Protection "Dust"<br />

Ex tD A21 IP6x T95˚C, T105˚C, T120˚C, T135˚C<br />

Electrode Circuit Um: 250 Vac/dc<br />

Excitation Circuit: 170V max<br />

Enclosure: IP66, IP67<br />

Maximum surface temperature:<br />

Maximum Surface<br />

Temperature<br />

T95°C (+203°F)<br />

T105°C (+221°F)<br />

T120°C (+248°F)<br />

T135°C (+275°F)<br />

Process Temperature<br />

–40°C to +70°C (–40°F to +158°F)<br />

–40°C to +85°C (–40°F to +185°F)<br />

–40°C to +120°C (–40°F to +248°F)<br />

–40°C to +150°C (–40°F to +302°F)<br />

T0812.EPS<br />

Ambient Temp.:<br />

PFA Lining; –40˚C to +60˚C (–40˚F to +140˚F)<br />

Ceramics Lining; –15˚C to +60˚C (+5˚F to +140˚F)<br />

(2) Installation<br />

WARNING<br />

•All wiring shall comply with local installation<br />

requirements and local electrical code.<br />

• In hazardous locations, the cable entry devices<br />

shall be of a certified IECEx flameproof type,<br />

suitable for the conditions of use and correctly<br />

installed.<br />

• Unused apertures shall be closed with suitable<br />

flameproof certified blanking elements. (The<br />

plug attached is certified as the flameproof and<br />

IP66 or IP67 as a part of this apparatus.)<br />

• In case of ANSI 1/2 NPT plug, ANSI hexagonal<br />

wrench should be applied to screw in.<br />

IM 01E20D01-01E