2.3 Storage Precautions<br />

If the instrument is to be stored for a long period of<br />

time after delivery, observe the following points.<br />

The instrument should be stored in its original<br />

packing condition in the storage location.<br />

Select a storage location that fulfils the following<br />

conditions:<br />

• A place where it will not be exposed to rain or<br />

water<br />

• A place subject to minimal vibrations or shocks<br />

• Temperature and humidity levels should be as<br />

follows:<br />

Temperature: -30 to 70°C<br />

Humidity: 5 to 80% RH (no condensation)<br />

The preferred ambient temperature and<br />

humidity levels are 25°C and approximately<br />

65% RH.<br />

If the <strong>AXF</strong> magnetic flowmeter is transferred to the<br />

installation site and stored without being installed,<br />

its performance may be impaired due to the infiltration<br />

of rainwater and so forth. Be sure to install and<br />

wire the <strong>AXF</strong> magnetic flowmeter as soon as<br />

possible after transferring it to the installation<br />

location.<br />

2. HANDLING PRECAUTIONS<br />

Explosion protected type:<br />

Explosion protect types can be installed in hazardous<br />

areas according to the types of gases for which<br />

they are certified. See the description in Chapter 8<br />

“EXPLOSION PROTECTED TYPE INSTRU-<br />

MENT” and “INSTALLATION AND OPERATING<br />

PRECAUTIONS FOR TIIS FLAMEPROOF<br />

EQUIPMENT” in this user's manual.<br />

2.4 Installation Location<br />

Precautions<br />

Select the installation location with consideration to the<br />

following items to ensure long-term stable operation of<br />

the instrument.<br />

Ambient Temperature:<br />

Avoid installing the instrument in locations with<br />

constantly fluctuating temperatures. If the location is<br />

subject to radiant heat from the plant, provide heat<br />

insulation or improve ventilation.<br />

Atmospheric Condition:<br />

Avoid installing the instrument in a corrosive<br />

atmosphere. In situations where this is unavoidable,<br />

consider ways to improve ventilation and to prevent<br />

rainwater from entering and being retained in the<br />

conduit pipes.<br />

Vibrations or Shocks:<br />

Avoid installing the instrument in a place subject to<br />

shocks or vibrations.<br />

2-2<br />

IM 01E20D01-01E