6. OUTLINE<br />

Polyurethane Rubber /Natural Soft Rubber /<br />

EPDM Rubber Lining:<br />

Size mm (in.)<br />

25 (1.0)<br />

to<br />

400 (16)<br />

500 (20)<br />

to<br />

1000 (40)<br />

1100 (44)<br />

to<br />

2000 (80)<br />

2200 (88)<br />

to<br />

2600 (104)<br />

Flow Velocity<br />

V m/s (ft/s)<br />

Standard Accuracy<br />

(Calibration code B)<br />

V 0.3 (1.0) 1.0 mm/s<br />

0.3 V 10<br />

(1.0) (33)<br />

0.35% of Rate<br />

V 0.3 (1.0) 1.75 mm/s<br />

0.3 V 1<br />

(1.0) (3.3)<br />

0.25% of Rate 1 mm/s<br />

1 V 10<br />

(3.3) (33)<br />

0.35% of Rate<br />

V 0.3 (1.0) 2.2 mm/s<br />

0.3 V 1<br />

(1.0) (3.3)<br />

0.4% of Rate 1 mm/s<br />

1 V 10<br />

(3.3) (33)<br />

0.5% of Rate<br />

V 1 (3.3) 8.5 mm/s<br />

1 V 10<br />

(3.3) (33)<br />

0.85% of Rate<br />

T09.EPS<br />

Enhanced dual frequency excitation(Option code HF2) :<br />

Standard accuracy 1 mm/ s<br />

Size 25 mm (1.0 in.) to 400 mm (16 in.)<br />

% of Rate<br />

1.2<br />

1.0<br />

0.8<br />

Pulse 0.6<br />

Output<br />

Accuracy 0.4<br />

0.35<br />

0.2<br />

0<br />

High Standard grade Accuracy<br />

0 1 2 6 8 10<br />

V[m/s]<br />

F14.EPS<br />

Size 500 mm (20 in.) to 1000 mm (40 in.)<br />

% of Rate<br />

1.2<br />

1.0<br />

0.8<br />

Pulse 0.6<br />

Output<br />

Accuracy 0.4<br />

0.35<br />

0.2<br />

0<br />

High Standard grade Accuracy<br />

0 1 2 6 8 10<br />

V[m/s]<br />

F16-1.EPS<br />

Size 1100 mm (44 in.) to 2000 mm (80 in.)<br />

% of Rate<br />

1.2<br />

1.0<br />

0.8<br />

Pulse 0.6<br />

Output 0.5<br />

Accuracy 0.4<br />

0.2<br />

0<br />

High Standard grade Accuracy<br />

0 1 2 6 8 10<br />

V[m/s]<br />

F16-2.EPS<br />

Size 2200 mm (88 in.) to 2600 mm (104 in.)<br />

% of Rate<br />

2.4<br />

2.0<br />

1.6<br />

Pulse 1.2<br />

Output<br />

Accuracy 0.85<br />

0.8<br />

0.4<br />

0<br />

High Standard grade Accuracy<br />

0 1 2 6 8 10<br />

V[m/s]<br />

F16-3.EPS<br />

Current Output “”: Pulse output accuracy plus 0.05%<br />

of Span<br />

Repeatability:<br />

0.1% of Rate (V 1 m/s (3.3 ft/s))<br />

0.05% of Rate 0.5 mm/s (V < 1 m/s (3.3 ft/s))<br />

Maximum Power Consumption:<br />

<strong>Integral</strong> <strong>Flowmeter</strong>: 12W<br />

Remote Flowtube: Combined with <strong>AXF</strong>A11: 20W<br />

Combined with <strong>AXF</strong>A14: 12W<br />

Insulation Resistance (*1):<br />

<strong>Integral</strong> <strong>Flowmeter</strong>:<br />

Between power supply terminals and ground<br />

terminalm : 100MΩ at 500V DC<br />

Between power supply terminals and input /output<br />

terminals : 100MΩ at 500V DC<br />

Between ground terminal and input/output<br />

terminals : 20MΩ at 100V DC<br />

Between input/output terminals : 20MΩ at 100V DC<br />

Remote Flowtube:<br />

Between excitation current terminal and signal /common<br />

terminals : 100MΩ at 500V DC<br />

Between signal terminals : 100MΩ at 500V DC<br />

Between signal terminals and common terminal (C) :<br />

100MΩ at 500V DC<br />

Withstand Voltage (*1):<br />

<strong>Integral</strong> <strong>Flowmeter</strong><br />

Between power supply terminals and ground terminal :<br />

1390V AC for 2 seconds<br />

Between power supply terminals and input/output<br />

terminals : 1390V AC for 2 seconds<br />

Remote Flowtube (option code JF3, KF2, CF1, and SF2)<br />

Between excitation current terminal and ground terminal<br />

: 1500V AC for 1 minute<br />

Between signal terminals and ground terminal :<br />

1500V AC for 1 minute<br />

Between signal terminals and excitation current terminal<br />

: 2000V AC for 1 minute<br />

Remote Flowtube (option code FF1)<br />

Between signal terminals and ground terminal : 500V<br />

AC for 1 minute or 600V AC for 1 second<br />

Between signal terminals and excitation current terminal<br />

: 2000V AC for 1 minute or 2400V AC for<br />

1 second.<br />

6-14<br />

IM 01E20D01-01E