<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />

Chapter 4: 4.5 Installation for single-bearing generators<br />

4.5.4 Installation to the engine (single-bearing generators)<br />

The minimum clearances <strong>and</strong> regulations for cooling given in the section above<br />

have to be met for installation.<br />

4.5.4.1 Sealing of the generator against the engine<br />

During installation a sealing has to be attached between the generator <strong>and</strong> the<br />

engine. The type of sealing depends on the used engine. The sealings prescribed<br />

for the different engines are listed in the following table.<br />

Engine Type of sealing Installation instructions<br />

B&S 12.5 HP / 14 HP VE1/877 or VE1/977 Press the sealing into the<br />

shaft opening in the end<br />

shield.<br />

Honda GX 390 K1V VE1/871 Bond the sealing into the<br />

Yamaha MZ 360 K<br />

corresponding clearance in the<br />

end shield.<br />

Yanmar L90 / L100 Fluid sealing Apply liquid sealant into the<br />

corresponding clearance in the<br />

end shield.<br />

Hatz 1D 60C<br />

No sealing required.<br />