Synchronous Generators BG 132 and BG 160
Synchronous Generators BG 132 and BG 160
Synchronous Generators BG 132 and BG 160
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />
Chapter 6, Maintenance<br />
1<br />
2<br />
red gray<br />
3<br />
Figure 30<br />
Installing the carbon brushes holder<br />
6.4.2 Replacing the ball bearings<br />
The ball bearings of the generator have to be replaced at least every 20.000<br />
hours of operation. However, if rough noises are detected at the ball bearings<br />
during the check prescribed every 5.000 hours of operation, the ball bearings<br />
have to be replaced earlier.<br />
We strongly recommend for these operations to remove the generator <strong>and</strong> to<br />
send it to the manufacturer or to an agency authorized by the manufacturer.<br />
Removing the generator is described in chapter 8 on page 93.<br />
Issue date: August 2002 91