<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />

Chapter 4: 4.6 Installation of two-bearing generators (<strong>BG</strong> <strong>132</strong>)<br />

4.6 Installation of two-bearing generators (<strong>BG</strong> <strong>132</strong>)<br />

For installing two-bearing generators of the size <strong>BG</strong> <strong>132</strong> proceed according to<br />

the descriptions in this section 4.6. Prior to installation, read <strong>and</strong> underst<strong>and</strong><br />

the safety precautions in section 4.1 as well as the sections 4.2 to 4.4 <strong>and</strong><br />

observe the instructions <strong>and</strong> information given there.<br />

CAUTION<br />

On both sides of the generator, a lifting eye bolt is provided for<br />

attaching lifting equipment. Lifting equipment may only be<br />

attached to the generator using these lifting eye bolts. Only<br />

appropriate lifting equipment may be used.<br />

4.6.1 Dimensions <strong>and</strong> mounting (two-bearing type, <strong>BG</strong> <strong>132</strong>)<br />

The minimum clearances <strong>and</strong> regulations for cooling given in the following<br />

section 4.6.2 have to be met for installation.<br />

The dimensions of the generator can be found in the drawing sheet included in<br />

the annex.<br />

The generator has to be fastened using four<br />

screws (min. requirements: M8 or<br />

comparable, quality 8.8). The fastening must<br />

be durable as well as shock <strong>and</strong> vibration<br />

resistant. The screws must be secured<br />

against self-acting unscrewing by suitable<br />

measures, e.g. a clamp collar according to<br />

4 fastening screws<br />

DIN 128.<br />

Tightening torque for fastening screws:<br />

M = 25 Nm<br />