07.05.2014 Views

Synchronous Generators BG 132 and BG 160

Synchronous Generators BG 132 and BG 160

Synchronous Generators BG 132 and BG 160

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />

Chapter 4: 4.7 Installation of two-bearing generators (<strong>BG</strong> <strong>160</strong>)<br />

4.7 Installation of two-bearing generators (<strong>BG</strong> <strong>160</strong>)<br />

For installing generators of the size <strong>BG</strong> <strong>160</strong> proceed according to the<br />

descriptions in this section 4.7. Prior to installation, read <strong>and</strong> underst<strong>and</strong> the<br />

safety precautions in section 4.1 as well as the sections 4.2 to 4.4 <strong>and</strong> observe<br />

the instructions <strong>and</strong> information given there.<br />

CAUTION<br />

On both sides of the generator, a lifting eye bolt is provided for<br />

attaching lifting equipment. Lifting equipment may only be<br />

attached to the generator using these lifting eye bolts. Only<br />

appropriate lifting equipment may be used.<br />

4.7.1 Dimensions <strong>and</strong> mounting (<strong>BG</strong> <strong>160</strong>)<br />

The minimum clearances <strong>and</strong> regulations for cooling given in section 4.7.2 must<br />

be met for installation. The dimensions of the generator can be found in the<br />

drawing sheet included in the annex.<br />

The generator has to be fastened using<br />

four screws (min. requirements: M12 or<br />

comparable, quality 8.8). The fastening<br />

must be durable as well as shock <strong>and</strong><br />

vibration resistant. The screws must be<br />

secured against self-acting unscrewing by<br />

suitable measures, e.g. a clamp collar<br />

according to DIN 128.<br />

4 fastening screws<br />

• Tightening torque for fastening screws:<br />

M = 87 Nm<br />

Fr max<br />

• Permissible load on the shaft:<br />

Fa max<br />

Fr max = 5000 N (measured at an axial<br />

distance of 60 mm from the shaft<br />

outlet in the end shield)<br />

Fa max = 500 N<br />

No other parts may be mounted to the mounting<br />

profiles of the generator housing.<br />

CAUTION<br />

62 Issue date: August 2002