Chapter 4: 4.5 Installation for single-bearing generators<br />
Apply appropriate sealing<br />
depending on the engine<br />
1<br />
2<br />
4x<br />
Figure 13<br />
Installation of single-bearing brush-type generators fastened<br />
with tension bolt<br />
When installing brushless single-bearing generators<br />
The following descriptions assume that you have already performed the removal<br />
prior to installation according to section 4.5.4.3 on page 42.<br />
The steps listed here replace the steps 1. to 8. on page 43.<br />
1. Apply the sealing to the removed front end shield of the generator as<br />
described in section 4.5.4.1 on page 37 (see also Figure 14).<br />
2. Set the removed front end shield with the sealing applied onto the engine<br />
flange <strong>and</strong> fasten it using the four screws (Figure 14/2).<br />
3. As shown in Figure 14, align the generator in front of the engine in a way,<br />
that the generator shaft lies in one line with the engine shaft. If necessary,<br />
support the generator accordingly.<br />