07.05.2014 Views

Synchronous Generators BG 132 and BG 160

Synchronous Generators BG 132 and BG 160

Synchronous Generators BG 132 and BG 160

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />

Chapter 6, Maintenance<br />

6.1 Maintenance overview<br />

Interval Maintenance operation To be performed by<br />

Every<br />

working day<br />

Monthly<br />

Every 1.000<br />

hours of<br />

operation<br />

Every 5.000<br />

hours of<br />

operation<br />

Every 20.000<br />

hours of<br />

operation<br />

Check the correct function of the insulation<br />

monitoring unit (if available).<br />

See section 5.6.3 on page 84.<br />

At the generator:<br />

• Visual inspection for contamination or<br />

damages. Cleaning if necessary.<br />

• If necessary, clean the plates <strong>and</strong> labels<br />

or replace them.<br />

• Check the cooling air openings for<br />

contamination or blocking <strong>and</strong> clean<br />

them, if necessary.<br />

See section 6.3 on page 88.<br />

At the control box (if mounted):<br />

• Visual inspection for contamination or<br />

damages. Cleaning if necessary.<br />

• Check the cover <strong>and</strong> the socket lids for<br />

waterproof locking.<br />

See section 6.3 on page 88.<br />

Only for brush-type generators:<br />

Check the carbon brushes<br />

See section 6.4.1 on page 89.<br />

Check the ball bearings by "listening".<br />

Replace, if necessary (rough noises at the<br />

bearings).<br />

User<br />

User<br />

User<br />

Qualified<br />

electrically skilled<br />

person<br />

Qualified<br />

skilled person<br />

Replace the ball bearings<br />

Manufacturer<br />

The st<strong>and</strong>ard maintenance interval for<br />

replacing the ball bearings is 20.000 hours.<br />

If necessary (see check every 5.000 hours),<br />

the ball bearings have to be replaced earlier.<br />

See section 6.4.2 on page 91.<br />

86 Issue date: August 2002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!