Synchronous Generators BG 132 and BG 160
Synchronous Generators BG 132 and BG 160
Synchronous Generators BG 132 and BG 160
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />
Chapter 8, Removal<br />
8.3.1 Removal of single-bearing brush-type generators<br />
Work prior to removal <strong>and</strong> removal of the carbon brushes holder<br />
1. Disconnect the electric connection cables of the generator as described in<br />
section 4.8 on page 70.<br />
2. Unscrew the two screws M8 x 45, spanner size 10 mm, (Figure 31/2) <strong>and</strong><br />
detach the sleeve (1).<br />
3. Remove both connection cables from the connection lugs of the carbon<br />
brushes holder (Figure 31/5). The connection cables are coded by the width<br />
of the connection lugs <strong>and</strong> therefore secured against interchanging.<br />
4. Unscrew the fastening screw of the carbon brushes holder <strong>and</strong> detach the<br />
carbon brushes holder (Figure 31/5).<br />
5. Refer to the following descriptions to continue the removal:<br />
- For shaft fastening by grub-screw continue on page 95.<br />
- For shaft fastening by tension bolt continue on page 97.<br />
1 2<br />
3<br />
4<br />
5<br />
Figure 31<br />
Work prior to removal of single-bearing brush-type generators<br />
94 Issue date: August 2002