Chapter 4: 4.5 Installation for single-bearing generators<br />
Installation<br />
NOTE<br />
For additional installation instructions for shaft fastening by<br />
tension bolt (instead of the grub-screw described here), please<br />
refer to section 4.5.4.4 on page 45.<br />
1. Screw the supplied grub-screw (Figure 11/1) into the engine shaft as far as it<br />
will go using an Allen wrench.<br />
2. Apply the sealing to the removed front end shield of the generator as<br />
described in section 4.5.4.1 on page 37.<br />
3. Set the removed front end shield (Figure 11/2) with the sealing applied onto<br />
the engine flange <strong>and</strong> fasten it using the four screws (Figure 11/3).<br />
4. Align the generator in front of the engine in a way, that the generator shaft<br />
lies in one line with the engine shaft. If necessary, support the generator<br />
accordingly.<br />
5. Push the generator against the engine <strong>and</strong> align the threaded hole of the<br />
generator shaft to the grub-screw screwed into the engine shaft.<br />
6. Screw the generator shaft by turning the fan impeller onto the grub-screw in<br />
the engine shaft as far as it will go. This pulls the generator housing against<br />
the front end shield already mounted on the engine.<br />
NOTE<br />
While screwing the generator shaft onto the grub-screw, align<br />
the generator with the front end shield mounted on the engine.<br />
It is not necessary to tighten the generator shaft on the grubscrew.<br />
It is sufficient, if the shaft is screwed onto the grubscrew<br />
as far as it will go, since the screw-connection tightens<br />
itself when the generator is loaded.<br />
For installation instructions for shaft fastening by tension bolt,<br />
please refer to section 4.5.4.4 on page 45.<br />
7. Fasten the end shield to the generator using four fastening screws (Figure<br />
12/2).<br />
8. Remount the fan impeller shroud (Figure 12/1).<br />
Issue date: August 2002 43