<strong>Synchronous</strong> <strong>Generators</strong> <strong>BG</strong> <strong>132</strong> / <strong>BG</strong> <strong>160</strong><br />

Safety precautions<br />

DANGER<br />

Risk of<br />

personal injury<br />

or death<br />

<strong>and</strong><br />

destruction<br />

hazard<br />

Never connect the generator to the public electricity supply<br />

network or to any other systems for power generation. Risk of<br />

death, fire <strong>and</strong> destruction hazard!<br />

Never connect several generators to each other. Risk of death,<br />

fire <strong>and</strong> destruction hazard!<br />

If the generator shall be connected to an existing power<br />

distribution network (e.g. a house wiring), it has to be<br />

ensured, that the system is completely <strong>and</strong> reliably<br />

disconnected from the public electricity supply network of the<br />

energy supply company. Reverse feeding into the public<br />

electricity supply network or network interconnection is not<br />

allowed. Reverse feeding involves mortal danger by electric<br />

shock for persons possibly working at the de-energized public<br />

electricity supply network. Due to network interconnection<br />

with the public electricity supply network, the generator can be<br />

damaged, burn or cause fire in electrical cables of the system.<br />

Grounding the neutral conductor of the generator (N, midpoint<br />

conductor) supersedes the protective measure "protection<br />

separation" <strong>and</strong> should therefore be avoided. If the neutral<br />

conductor N shall be grounded anyway, this may only be<br />

performed by an electrically qualified person. In this case, a<br />

current-operated earth-leakage circuit breaker has to be<br />

connected on the load side of the generator output. The<br />

efficiency of the electrical protective measure has to be<br />

confirmed by an appropriate measurement.<br />

The generator supplies highly dangerous voltages during<br />

operation! Never touch the generator or the devices connected<br />

to the generator with wet h<strong>and</strong>s during operation. Mortal<br />

danger by electric shock!<br />

Generator components may be very hot, not just during but also<br />

after operation. Burning hazard!<br />

The generator may only be operated with the protective covers<br />

for the drive mounted as specified. Risk of personal injury!<br />

8 Issue date: August 2002