Strategy and Planning Committee Agenda 16 February 2011<br />

Plan Rev. Plan Name Date<br />

Architecture<br />

Amendments 1 Replace the solid balustrades of the first floor balconies with<br />

glass;<br />

2 The solid dividing wall between the two balconies above the<br />

maximum balustrade height at first floor level must be set<br />

back a minimum of 5m from the front boundary. The<br />

remainder of the dividing wall is to have a height no greater<br />

than the maximum balustrade height<br />

3 A minimum 2 metre wide landscaping bed must be<br />

established at the front of the balconies at the first level<br />

4 The building wall of the medical centre (eastern side) must<br />

include 40% glazing;<br />

5 The building wall of the ground level studio unit (western<br />

side) must consist of rock cladding; and<br />

6 A minimum 1 metre wide landscaping bed must be<br />

established on the eastern side of the lobby on the ground<br />

level<br />

Plan Rev. Plan Name Date<br />

10012 SD04 D Sections, drawn by MS of Sprout 22.12.10<br />

Architecture<br />

Amendments 1 Replace the solid balustrades of the first floor balconies with<br />

glass;<br />

2 The solid dividing wall between the two balconies above the<br />

maximum balustrade height at first floor level must be<br />

setback a minimum of 5m from the front boundary. The<br />

remainder of the dividing wall is to have a height no greater<br />

than the maximum balustrade height<br />

3 A minimum 2 metre wide landscaping bed must be<br />

established at the front of the balconies at the first level; and<br />

4 The building wall of the ground level studio unit (western<br />

side) must consist of rock cladding<br />

Plan Rev. Plan Name Date<br />

Drawing No. B Stormwater Management Plan – Job Ref No 01.10.10<br />

MODEL<br />

SC2650, Drawn by SFD, August 2010<br />

Amendments 1 The bio-filter component must be amended to include a<br />

drainage layer and transitional layer as described in the<br />

Healthy Waterways Construction and Establishment<br />

Guidelines for Vegetated Systems<br />

2 Overflow pits as described in the Healthy Waterways<br />

Construction and Establishment Guidelines for Vegetated<br />

Systems must be provided to the bioretention component<br />

3 To prevent lateral flow, an impermeable wall must be<br />

provided between the bioretention and detention/infiltration<br />

components. Water that exceeds the extended detention<br />

depth needs to be directed via piping from the overflow pits to<br />

the infiltration system to prevent short circuiting of filtrate<br />

through lateral flow and subsequent leaking out of untreated<br />

water<br />