ill-24<br />

III. B-2<br />

BRINE DISPOSAL VIA INJECTION INTO<br />

APPLICABLE UNDERGROUND FORMATIONS<br />

In a major oil and gas produc<strong>in</strong>g State such as Texas, <strong>the</strong> framework and procedures <strong>for</strong> proper<br />

underground disposal of br<strong>in</strong>es are <strong>in</strong>herent <strong>in</strong> hydrocarbon production regimes.<br />

Thousands of disposal permits have been issued by <strong>the</strong> Texas Railroad Commission (TRC), which has<br />

pr<strong>in</strong>cipal jurisdiction over this alternative <strong>for</strong> br<strong>in</strong>e disposal. There are four major parameters <strong>for</strong><br />

allowable underground disposal that are key to <strong>the</strong> acquisition of an appropriate disposal permit, namely:<br />

A. Proper analyses of exist<strong>in</strong>g well logs to select receiv<strong>in</strong>g <strong>for</strong>mations<br />

B. Porosity, permeability and reservoir capacity data <strong>in</strong> selected <strong>for</strong>mations<br />

C. Proper design of <strong>in</strong>jection well(s) and surface systems<br />

D. Pressure and flow constra<strong>in</strong>ts <strong>for</strong> <strong>in</strong>tended pump<strong>in</strong>g rates <strong>in</strong>to receiv<strong>in</strong>g <strong>for</strong>mations<br />

Certa<strong>in</strong> o<strong>the</strong>r constra<strong>in</strong>ts may also be relevant but, <strong>in</strong> general, satisfaction of <strong>the</strong> above four parameters<br />

is generally tantamount to permit approval.<br />

Certa<strong>in</strong> factors unique to <strong>GP</strong>/<strong>GT</strong> br<strong>in</strong>es are also significant <strong>in</strong> reservoir evaluation prior to selection of<br />

<strong>the</strong> proper receiv<strong>in</strong>g <strong>for</strong>mations. These are <strong>the</strong> temperatures and flow rates of <strong>the</strong> br<strong>in</strong>es <strong>in</strong> question and<br />

<strong>the</strong> necessity to plan <strong>for</strong> adequate reservoir capacity <strong>in</strong> a given <strong>for</strong>mation, such that disposal may proceed<br />

over a reasonably long period of time, at least ten years.<br />

A good prelim<strong>in</strong>ary idea of <strong>the</strong> capacity of some South Texas receiv<strong>in</strong>g <strong>for</strong>mations may be derived from<br />

referr<strong>in</strong>g back to <strong>the</strong> <strong>in</strong>troduction to this Section ill B, on page 16, where<strong>in</strong> a professional, <strong>in</strong>dependent<br />

organization active <strong>in</strong> br<strong>in</strong>e disposal has stated that: "<strong>in</strong>jection of 20,000 BBLlDay <strong>in</strong>to five 6,000 foot<br />

wells of reasonable cost is possible.... If operated <strong>for</strong> 15 years, <strong>the</strong> receiv<strong>in</strong>g reservoir will need to store<br />

2.2 x Hf BBL". In TWOB terms, that quantity equals 285,000 acre-feet over 15 years, or roughly a<br />

little less than 2,000 acre-feet per year.<br />

The qualify<strong>in</strong>g procedures and o<strong>the</strong>r relevant details are here<strong>in</strong> excerpted and reproduced from <strong>the</strong> TRC<br />

Manual entitled: "Underground Injection Control Reference Manual", April 1992 Revision. (please refer<br />

to Appendix B).<br />

In summary, Underground Disposal of Br<strong>in</strong>es <strong>in</strong> Texas is a well <strong>for</strong>mulated and highly standardized<br />

technique that represents a particularly cost-effective and environmentally safe method of br<strong>in</strong>e disposal.