11.10.2014 Views

(GP/GT) for Additional Water Supply in the Lower Rio Grande

(GP/GT) for Additional Water Supply in the Lower Rio Grande

(GP/GT) for Additional Water Supply in the Lower Rio Grande

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

~nderground hydrocarbon storage.facll!ty wells. Project permits provide that new wells<br />

drilled or converted after <strong>the</strong> project was Orig<strong>in</strong>ally approved must be permitted by <strong>the</strong><br />

Commission.<br />

Temporary Authorities<br />

Where an emergency or o<strong>the</strong>r good cause exists, a temporary authority may be issued on<br />

an expedited basis If, <strong>in</strong> <strong>the</strong> Director's judgement. <strong>the</strong> operation Is not likely to affect o<strong>the</strong>r<br />

parties or cause pollution of fresh water. A temporary au thori ty so issued will be suspended.<br />

If a protest Is received In accordance with Statewide Rules prior to <strong>the</strong> i~suance of a regular<br />

permit. .<br />

Geological Requirements<br />

The geological <strong>for</strong>mation or authOrized strata must be Isolated from overly<strong>in</strong>g or<br />

underly<strong>in</strong>g strata that conta<strong>in</strong> oil, gas, geo<strong>the</strong>rmal, water or o<strong>the</strong>r resources by sufficient<br />

thickness of relatively impermeable strata. A suffiCient thickness of relatively Impermeable<br />

strata Is generally conSidered to consist of an accumulative total of 250 feet of clay or shale.<br />

Variances In <strong>the</strong> total thickness required to effectively separate are conSidered on <strong>the</strong> basis<br />

of cont<strong>in</strong>uity of strata, thickness of Individual stratum and <strong>the</strong> presence of relatively<br />

Impermeable strata o<strong>the</strong>r than clay or shale. No Class II well will be permitted where faults,<br />

fractures. structure or o<strong>the</strong>r geologic factors Indicate that isolation of <strong>the</strong> authorized zone is<br />

Jeopardized. The operator must submit adequate geological <strong>in</strong><strong>for</strong>mation to show<br />

compliance with this requirement.<br />

cas<strong>in</strong>g and Cement<strong>in</strong>g<br />

Class II wells must be cased and cemented <strong>in</strong> accordance with Rule 13 to prevent <strong>the</strong><br />

movement of fluids <strong>in</strong>to sources of fresh water. Rule 13 requires that surface cas<strong>in</strong>g be set<br />

and cemented so as to protect fresh water strata, as def<strong>in</strong>ed by <strong>the</strong> Texas <strong>Water</strong> CommiSSion.<br />

Cement<strong>in</strong>g Is required to be circulated to <strong>the</strong> surface by <strong>the</strong> pump and plug method. and <strong>the</strong><br />

specifications <strong>for</strong> cement quality and cas<strong>in</strong>g Integrity set out In <strong>the</strong> Rule must be met.<br />

Wells that are converted from producers to Injection Into <strong>the</strong> same productive <strong>for</strong>mation<br />

meet UIC cement<strong>in</strong>g requirements If <strong>the</strong>y were completed In compliance with Rule 13.<br />

Wells that are converted to disposal Into a <strong>for</strong>mation above <strong>the</strong> productive <strong>for</strong>mation must<br />

meet UIC criteria of adequate cement to conf<strong>in</strong>e <strong>the</strong> <strong>in</strong>jected fluids. These criteria are 100<br />

feet of bonded cement as determ<strong>in</strong>ed from a bond log, 250 feet of cement as evidenced by a<br />

temperature survey, or 400 to 600 feet of cement determ<strong>in</strong>ed byslunyy1eld calculation. The<br />

flexibll!ty <strong>in</strong> annular footage allows <strong>for</strong> consideration of <strong>the</strong> type of cement used and <strong>the</strong><br />

characteristics of <strong>the</strong> <strong>for</strong>mation.<br />

Area of Review<br />

StateWide Rules require that Class II disposal and <strong>in</strong>jection well operators mustexamJne<br />

<strong>the</strong> data of record <strong>for</strong> wells that penetrate <strong>the</strong> proposed <strong>in</strong>jection zone with<strong>in</strong> a one quarter<br />

(114) mile radl us of <strong>the</strong> proposed well to determ<strong>in</strong>e If all abandoned wells have been plugged <strong>in</strong><br />

a manner that w1ll prevent <strong>the</strong> movement of fluids <strong>in</strong>to strata o<strong>the</strong>r than <strong>the</strong> authOrized<br />

zone. Appl!cants <strong>for</strong> new permits must submit a map show<strong>in</strong>g <strong>the</strong> location of all wells of<br />

public record with<strong>in</strong> 1/4 mile as part of <strong>the</strong>ir permit application. For those wells that<br />

penetrate <strong>the</strong> top of <strong>the</strong> Injection zone, <strong>the</strong> applicant must attach a tabulation of <strong>the</strong> wells<br />

show<strong>in</strong>g <strong>the</strong> dates <strong>the</strong> wells were drilled and <strong>the</strong> present status of <strong>the</strong> wells. Alternatively, if<br />

11<br />

....

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!