(5) At the 20 th minute the test ends, the participant is debriefed <strong>and</strong> interviewed, <strong>and</strong><br />

their questionnaire is collected.<br />

Testing Procedures <strong>for</strong> Participants First Exposed to the Commercial System<br />

(1) Participants start with the commercial system with the initial desktop illuminance<br />

of 500 lux, use the remote controller to override the initial condition to a<br />

com<strong>for</strong>table level, <strong>and</strong> begin working on the task of their choosing.<br />

(2) At the 5 th , 10 th <strong>and</strong> 15 th minute the lights are again dimmed or brightened by the<br />

investigator using a second remote control, without notifying the participants.<br />

(3) At the 20 th minute the investigator will stop the first set of the experiment <strong>and</strong><br />

ask the participant to take a 10-minute rest outside the office. Meanwhile, the<br />

investigator will switch the lighting to the mote-based research system, <strong>and</strong> set<br />

the initial desktop illuminance to 500 lux. Participants will be asked to use the<br />

GUI to override the initial condition to a com<strong>for</strong>table level after settling <strong>for</strong> the<br />

remaining experiment.<br />

(4) At the 5 th , 10 th <strong>and</strong> 15 th minute of the second set experiment the lights are<br />

dimmed or brightened by the investigator with the GUI at the investigator station.<br />

(5) At the 20th minute the test ends, the participant is debriefed <strong>and</strong> interviewed, <strong>and</strong><br />

their questionnaire is collected.<br />

(6) After the participant leave, the investigator will resume the remaining procedure<br />

of the sensor placement experiment <strong>and</strong> gather photosensor <strong>and</strong> light meter<br />

measurement as described in previous section.<br />