Luminaire surface depreciation: 1.0 Luminaire dirt depreciation (LDD): 0.85<br />

Total light loss factor, LLF (product of individual factors above): 0.748<br />

CALCULATIONS<br />

(Average Maintained Illumination Level)<br />

( Maintained Illuminance) Area of Room<br />

Number of Luminaires =<br />

( Lumens per Luminaire) ( CU) ( LLF)<br />

( )<br />

( 500) ( 15 10)<br />

=<br />

= 14.27 15<br />

( 10,640) ( 0.66) ( 0.748) 257