<strong>BaseStation</strong> <strong>3200</strong> Advanced Irrigation Controller <strong>Manual</strong><br />

7. Verify communications from the <strong>BaseStation</strong> to the flow biCoder and complete the configuration and setup.<br />

Refer to Searching for Flow biCoders (including those associated with a Master Valve) on page 37 and to<br />

Configuring Flow biCoders, Flow Meters, and Flow Sensors on page 41.<br />

Wiring a Water Meter<br />

You must use a water meter register that provides at least 10 pulses per gallon. The “pulse reed switch” register<br />

does not generate enough pulses per gallon for meaningful flow measurements for many installations. Netafim<br />

water meters will operate across a large range of flow rates and are a good choice where extended range is<br />

important. You can find more information at http://www.netafim.com, or contact your local distributor.<br />

You must have a water meter and register (pipe size and flow rate) that will generate at least 100 pulses per<br />

minute to have reasonable flow readings, 200 pulses per minute is better.<br />

1. Use a biasing resistor in any three-wire flow meter voltage line.<br />

2. Use the following formula to calculate the K-value, and then enter these values into the appropriate menu on<br />

your <strong>BaseStation</strong> <strong>3200</strong>. Refer to Configuring a Flow Device on page 57.<br />

Examples:<br />

10 Gal/Min and 10 Pulses/Gal<br />

(provides 100 pulses per minute)<br />

K-value = 6.00 (accuracy about 5%)<br />

25 Gal/Min and 10 pulses/gal<br />

(provides 250 pulses per minute)<br />

K-value = 6.00 (accuracy about 2%)<br />

blue<br />

BL-NE01<br />

Blinks when the<br />

two wire is<br />

communicating<br />

yellow<br />

BL-5304<br />

White<br />

Blinks for every 4 th pulse<br />

clear<br />

yellow<br />

Cable shielding must<br />

be fully covered by<br />

water-proof tube<br />

DBR-6 or DBG or<br />

equivalent submersion<br />

proof connectors<br />

To <strong>BaseStation</strong><br />

DBY or equivalent<br />

waterproof connectors<br />

Netafim ‘M’<br />

Water Meter<br />

Page 29