<strong>BaseStation</strong> <strong>3200</strong> Advanced Irrigation Controller <strong>Manual</strong><br />

5. Press the NEXT button to move to the First Zone Delay field, and then press the + or – button to set the<br />

amount of time that you want the system to delay before the zone starts running.<br />

Note: Use the First Zone Delay setting to give you time to walk to the zone location so you can observe the<br />

zone running. You can set the delay time from 0 seconds to 10 minutes.<br />

6. Press the NEXT button to move to the Between Zone Delay field, and then press the + or – button to set the<br />

amount of time that you want the system to delay before another zone starts running.<br />

Note: If you are only running one zone, you can leave this field set to 0<br />

(zero).<br />

7. When you have finished making changes, turn the dial to the Auto Run<br />

position. When the manual run starts, the main screen shows the<br />

details.<br />

8. If you want to stop the manual run while it is active, press the CLR<br />

button.<br />

Note: When the manual run is complete, the controller changes the<br />

<strong>Manual</strong>ly Run Zone(s) setting to OFF.<br />

<strong>Manual</strong>ly Running All Zones<br />

1. Turn the dial to the <strong>Manual</strong> Water position.<br />

2. Make sure that the first field on the screen says <strong>Manual</strong>ly Run Zone(s).<br />

If another option displays in this field, press the + button to change the<br />

option to <strong>Manual</strong>ly Run Zone(s).<br />

3. Press the NEXT button to move to the next field, and then press the +<br />

or – button to select All. If the field is set to OFF, press the + button<br />

one time to change the field to the lowest numbered zone, and then<br />

press the – button one time to change the setting to All.<br />

Note: If you decide that you do not want to start a manual run after<br />

you have selected All, press the CLR button to change the setting to<br />

OFF.<br />

4. Press the NEXT button to move to the Zone Run Time field, and then press the + or – button to set the<br />

amount of time that you want each zone to run.<br />

5. Press the NEXT button to move to the First Zone Delay field, and then press the + or – button to set the<br />

amount of time that you want the system to delay before the first zone starts running.<br />

Note: Use the First Zone Delay setting to give you time to walk to the zone location so you can observe the<br />

zone running.<br />

6. Press the NEXT button to move to the Between Zone Delay field, and<br />

then press the + or – button to set the amount of time that you want<br />

the system to delay before another zone starts running.<br />

7. When you have finished making changes, turn the dial to the Auto Run<br />

position. When the manual run starts, the main screen shows the<br />

details.<br />

8. If you want to stop the manual run while it is active, press the CLR<br />

button.<br />

Note: When the manual run is complete, the controller changes the <strong>Manual</strong>ly Run Zone(s) setting to OFF.<br />