Technical data<br />

13.2 TAINY EMOD-V3-IO, TAINY EMOD-L3-IO<br />

Interfaces Applicat<strong>io</strong>n<br />

interface<br />

Security<br />

funct<strong>io</strong>ns<br />

Addit<strong>io</strong>nal<br />

funct<strong>io</strong>ns<br />

2x 10/100 Base-T (RJ45 plug)<br />

Ethernet IEEE802, 10/100 Mbit/s<br />

Service interface USB-A (reserved for later applicat<strong>io</strong>ns)<br />

VPN<br />

Firewall<br />

VPN IPSec (TAINY HMOD-V3-IO only)<br />

Stateful inspect<strong>io</strong>n firewall<br />

Anti-spoofing<br />

Port forwarding<br />

DNS cache, DHCP server, NTP, remote logging, connect<strong>io</strong>n<br />

monitoring, alarm-SMS<br />

Management Web-based administrat<strong>io</strong>n user interface, SSH console<br />

Wireless<br />

connect<strong>io</strong>n<br />

Ambient<br />

condit<strong>io</strong>ns<br />

Frequency bands Quad band: GSM 850/900/1800/1900MHz<br />

EDGE (EGPRS) Multislot Class 12<br />

Mobile Stat<strong>io</strong>n Class B<br />

GPRS Multislot Class 12<br />

Modulat<strong>io</strong>n and Coding Scheme MCS 1 – 9<br />

Full PBCCH support<br />

Mobile Stat<strong>io</strong>n Class B<br />

Coding Scheme 1 – 4<br />

CSD / MTC V.110, RLP, non-transparent<br />

2.4, 4.8, 9.6, 14.4kbps<br />

SMS (TX) Point to point, MO (outgoing)<br />

Max.<br />

transmiss<strong>io</strong>n<br />

power (in<br />

accordance with<br />

output 99, V5)<br />

Antenna<br />

connect<strong>io</strong>n<br />

Temperature<br />

range<br />

Class 4 (+33dBm ±2dB) for EGSM850<br />

Class 4 (+33dBm ±2dB) for EGSM900<br />

Class 1 (+33dBm ±2dB) for EGSM850<br />

Class 1 (+30dBm ±2dB) for GSM1900<br />

Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK<br />

Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK<br />

Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK<br />

Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK<br />

Nominal impedance: 50 ohms, jack: SMA<br />

Betrieb: -20 °C bis +60 °C *)<br />

Lagerung: -40 °C bis +70 °C<br />

*) Automatic shut-down of the rad<strong>io</strong> module in case of reaching a critical<br />

temperature.<br />

Air humidity 0-95 %, non-condensing<br />

Housing Design Top-hat rail housing<br />

Material Plastic<br />

Page 110 of 111 TAINY xMOD