Installation and Mounting5. Installation and MountingThe sensor is an optical sensor for measurements with micrometer accuracy.iMake sure it is handled carefully when installing and operating.5.1 Sensor Mounting ILD <strong>1402</strong>-xMount the sensor via 2 screws M4.Mount the sensor in such a way thatthe laser beam is directed perpendicularlyonto the surface of the target.In case of misalignment it is possiblethat the measurement results will notalways be accurate, see Chap. 9..also.20 (.79)14 (.55)48 (1.89)12 (.47)PossibleconnectororientationMinimum bending radius PC<strong>1402</strong>-x--once: 39 mm--continuous: 78 mm--cable ø PC <strong>1402</strong>-x: 8 mmRotate the connector:Loosen the 4 screws M2 and rotatethe male connector.Fasten the male connector. Use newsealing screws M2. Connector issealed (IP 67) waiting 12 hours.Fig. 4 Dimensional drawing ILD<strong>1402</strong>-x,dimensions in mm (inches), not to scale65 (2.56)50 (1.97)40 (1.57)5(.20)2 Mounting holesø4.3/5.8Laser beam16 (.63)57 (2.24)65 (2.56)80 (3.15)4(.16)M12x1<strong>optoNCDT</strong> <strong>1402</strong>Page 20