Serial Interface RS4228.4.6 Reading the Sensor Settings, GET_SETTINGSName: GET_SETTINGSDescription: Supplies the current sensor settings.Swap the received bytes according, see Chap. 8.2.1.These are as follows:Output channel--0 = Current--1 = DigitalTeach value 10.0 … 16368.0e. g. float: 3027.426 = hexadecimal: 0x453d36d1Teach value 20.0 … 16368.0e. g. float: 11068.851 = hexadecimal: 0x462cf367Analog error handler--0 = hold last value--1 = error output--2…99 hold last value for 2…99 images respectively cyclesAverage type--0 = moving average--1 = MedianAverage value--1…128 moving average, if average type = 0--3, 5, 7, 9 Median, if average type = 1Measurement rate--0 = 1500 Hz--1 = 1000 Hz--2 = 750 Hz--3 = 375 Hz--4 = 50 HzBaud rate--0 = 115200 Baud--1 = 57600 Baud--2 = 38400 Baud--3 = 19200 Baud--4 = 9600 BaudDigital output type--0 = Binary--1 = ASCIIAnalog, digital output mode--0 = continuously each measurement, depending on baud rateand the measuring frequency;delay = (Bit quantity / Baud rate) * measuring frequency [Hz](if delay < 0, delay = delay +1)delay = number of cycles with no serial output--1 = time-based, see output time [ms]--2 = trigger controlled, see external input modeOutput time [ms]1…65535Key lock--0 = key enabled--1 = key locked--2 = automatic key lock after 5 min power is on<strong>optoNCDT</strong> <strong>1402</strong>Page 55