Serial Interface RS422Default setting:115200 Baud8.4.14 Set Baud Rate, SET_BAUDRATEName:Description:Parameter:--X = 0 --> 115200--X = 1 --> 57600--X = 2 --> 38400--X = 3 --> 19200--X = 4 --> 9600SET_BAUDRATESets the transmission rate.The sensor still sends the reply with the old baud rate and only switches to the new baud rate once the replyhas been sent. The output rate reduces automatically when the baud rate is changed because individualmeasurement values are skipped.Do not forget to change your programs baud rate.iFormat: 31 24 23 16 15 8 7 0 hex„+“ „+“ „+“ 0x0d („CR“) 0x2B2B2B0D„l“ „L“ „D“ „1“ 0x494C44310x20 0x80 0x00 0x03 0x208000030x00 0x00 0x00 0x0X 0x0000000XReply: 31 24 23 16 15 8 7 0 hex„l“ „L“ „D“ „1“ 0x494C44310xA0 0x80 0x00 0x02 0xA08000020x20 0x20 0x0D 0x0A 0x20200D0A<strong>optoNCDT</strong> <strong>1402</strong>Page 65