Serial Interface RS422Default setting:„Error code“, also3.75 mA on the analogoutput8.3.7 Sensor Behavior in Error Case, SAVELASTMVName:Description:SAVELASTMVSwitches between „Hold last value“ and „Error code“ of the analog output.Format Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9“+” “+” “+” 0x0D „I“ „L“ 0x0F 0x01 Output typeReply Byte 1 Byte 2 Byte 3 Byte 4 Byte 5„I“ „L“ 0x8F 0x00 noneCommand error-freeByte 1 Byte 2 Byte 3 Byte 4 Byte 5“I“ “L“ 0xCF 0x01 Error codeFaulty commandOutput typeDescription Bytes ValueOutput type = „Hold last value“ (in the case of an error the last valid measured value isshown on the analog output)1 0Output type = „Error code“ (in the case of an error a value < 4 mA is output) 1 1<strong>optoNCDT</strong> <strong>1402</strong>Page 48