Manual optoNCDT 1402 - Micro-Epsilon

Manual optoNCDT 1402 - Micro-Epsilon

Manual optoNCDT 1402 - Micro-Epsilon

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Serial Interface RS422Default setting:error value8.4.13 Error Output (Analog output), SET_ANALOG_ERROR_HANDLERName:Description:SET_ANALOG_ERROR_HANDLERHold or not hold last measurement value.Parameter:--X = 0 --> hold last measurement value--X = 1 --> error value (3.75 mA)--X = 2 … 99 --> hold last measurement value for 2 … 99 images respectively cyclesThis command only affects the analog output. If set to X = 0, the last valid measurement value will continueto be issued if an error occurs (no object, invalid object, object outside the measurement range or laserturned off). If set to X = 1, an error signal will be generated for the current output that has an error value of3.75 mA. If set to X = 2 ... 99, the last valid measurement value will continue to be issued for X measuringcycles before an error signal is generated on the analog output.Format: 31 24 23 16 15 8 7 0 hex„+“ „+“ „+“ 0x0d („CR“) 0x2B2B2B0D„l“ „L“ „D“ „1“ 0x494C44310x20 0x81 0x00 0x03 0x208100030x00 0x00 0x00 0x0X 0x0000000XReply: 31 24 23 16 15 8 7 0 hex„l“ „L“ „D“ „1“ 0x494C44310xA0 0x81 0x00 0x02 0xA08100020x20 0x20 0x0D 0x0A 0x20200D0A<strong>optoNCDT</strong> <strong>1402</strong>Page 64