Serial Interface RS4228.4.22 Reset Sensor, RESET_BOOTName:Description:RESET_BOOTStarts the sensor’s initialization phase. Duration about 900 ms.Procedure: The sensor replies and then re-boots. The string of the boot message contains “CI140x“, “CR““LF“ and the answer of “GET_INFO“.Format: 31 24 23 16 15 8 7 0 hex„+“ „+“ „+“ 0x0d („CR“) 0x2B2B2B0D„l“ „L“ „D“ „1“ 0x494C44310x20 0xF0 0x00 0x02 0x20F00002Antwort: 31 24 23 16 15 8 7 0 hex„l“ „L“ „D“ „1“ 0x494C44310xA0 0xF0 0x00 0x02 0xA0F000020x20 0x20 0x0D 0x0A 0x20200D0A8.4.23 Set Default Setting, SET_DEFAULTName: SET_DEFAULTDescription: Resets the set parameters to the default settings (factory settings).This concerns:--Data protocol ILD1401• Output channel: 0 --> analog output,• Analog error handler: 1 --> in the case of an error: 3.75 mA on the analog output,• Filter: 0 = Median off,--Data protocol ILD<strong>1402</strong>• Output channel: 0 --> analog output,• Teach value 1 --> 0.0• Teach value 2 --> 16368.0• Analog error handler: 1 --> in the case of an error: 3.75 mA on the analog output,• Average type: 0 --> moving average,• Average value: 1 --> no averaging,<strong>optoNCDT</strong> <strong>1402</strong>Page 73